![Rohde & Schwarz 1321.1211.02 User Manual Download Page 492](http://html1.mh-extra.com/html/rohde-and-schwarz/1321-1211-02/1321-1211-02_user-manual_1477772492.webp)
Remote Commands
R&S
®
Cable Rider ZPH
485
User Manual 1321.0950.02 ─ 07
RECeiver
receiver
MAPS
map
ACT
cable and antenna analyzer
*RST:
SAN
Example:
INST SAN
Selects spectrum analyzer mode.
INSTrument:NSELect
<OperatingMode>
This command selects the operating mode.
Parameters:
<OperatingMode>
1
spectrum analyzer
5
power meter
18
analog modulation
*RST:
1
Example:
INST:NSEL 1
Selects spectrum analyzer mode.
14.6.5.7
Setting Measurement Configuration
The following chapter describes command necessary to set the measurement configu-
ration.
List of commands
CALCulate<1...2>:FSK:DEViation:REFerence[:VALue]
.......................................................485
[SENSe:]DDEMod:BURSt[:STATe]
................................................................................... 486
[SENSe:]DDEMod:FILTer:ALPHa
.....................................................................................486
[SENSe:]DDEMod:FILTer:NAME
......................................................................................486
[SENSe:]DDEMod:FILTer[:STATe]
.................................................................................... 487
[SENSe:]DDEMod:SRATe
............................................................................................... 487
[SENSe:]DDEMod:TIME
................................................................................................. 487
CALCulate<1...2>:FSK:DEViation:REFerence[:VALue]
<FrequencyDeviation>
This command sets and queries the frequency deviation in the FSK signal.
The numeric suffix at CALCulate is irrelevant for this command
Suffix:
<1...2>
.
1...2