Performance Monitoring (PM)
A connection’s performance is monitored by inspecting blocks of cells (delimited by forward monitoring
cells) sent between connection or segment endpoints. Each forward monitoring cell (FMC) contains
statistics about the immediately preceding block of cells. When an endpoint receives an FMC, the statistics
generated locally across the same block are added to produce a backward reporting cell (BRC), which is
then returned to the opposite endpoint.
Up to 64 bidirectional or unidirectional block tests are supported simultaneously for each controller (SCC
or UTOPIA). When running a PM test, FMCs are generated for the transmit direction and terminated in
the receive direction. The user may choose to activate PM in any direction by setting the PM bit in the
receive connection table (RCT), transmit connection table (TCT) or both for a bidirectional PM test.
Figure 39-4
shows the FMC and BRC structure.
Figure 39-4. Performance Monitoring Cell Structure (FMCs and BRCs)
Table 39-2
describes performance monitoring cell fields.
Table 39-2. Performance Monitoring Cell Fields
Field
Description
BRC
FMC
MCSN
Monitoring cell sequence number. The sequence number of the performance monitoring
cell (modulo 256).
Yes
Yes
TUC
0+1
Total user cell 0+1 count. Counts all user cells (modulo 65,536) sent before the FMC was
inserted.
Yes
Yes
TUC
0
Total user cell 0 count. Counts CLP = 0 user cells (modulo 65,536) sent before the FMC
was inserted.
Yes
Yes
Header = 5 bytes
Payload = 48 bytes
0010 = Performance Monitoring
OAM
Cell
Type
Function
Type
GFC/ VPI
VCI
PTI
CLP HEC
Function
Specific
Fields
Reserved
VPI
4
4
6
45 x 8
10
CRC-10
Unused
2 octets
4 octets
1 octet
29 octets
2 octets
Time-
Stamp
Total User
Cell 0+1
2 octets
Count
1 octet
0000 = Forward Monitoring (FMC)
0001 = Backward Reporting (BRC)
Monitoring
Sequence
Number
Block
Error
Result
Total
Received
Cells 0+1
2 octets
Total User
Cell 0
Count
2 octets
Total
Received
Cells 0
Block Error
Detection
Code
(MCSN)
(TUC0+1)
(BEDC0+1)1 (TUC0)
(TSTP)
(TRCC0)2
(BLER)2 (TRCC0+1)2
• 1. BEDC
0+1
appears in FMCs only.
• 2.
TRCC
0
, BLER, and TRCC
0+1
appear in BRCs only.
Summary of Contents for PowerQUICC MPC870
Page 98: ...MPC885 PowerQUICC Family Reference Manual Rev 2 I 4 Freescale Semiconductor ...
Page 118: ...MPC885 Overview MPC885 PowerQUICC Family Reference Manual Rev 2 1 20 Freescale Semiconductor ...
Page 158: ...The MPC8xx Core MPC885 PowerQUICC Family Reference Manual Rev 2 3 18 Freescale Semiconductor ...
Page 288: ...MPC885 PowerQUICC Family Reference Manual Rev 2 III 4 Freescale Semiconductor ...
Page 554: ...MPC885 PowerQUICC Family Reference Manual Rev 2 V 6 Freescale Semiconductor ...
Page 1090: ...UTOPIA Interface MPC885 PowerQUICC Family Reference Manual Rev 2 43 8 Freescale Semiconductor ...
Page 1312: ...Byte Ordering MPC885 PowerQUICC Family Reference Manual Rev 2 A 8 Freescale Semiconductor ...
Page 1336: ...MPC885 PowerQUICC Family Reference Manual Rev 2 D 16 Freescale Semiconductor ...
Page 1358: ...MPC885 PowerQUICC Family Reference Manual Rev 2 D 38 Freescale Semiconductor ...
Page 1370: ...MPC880 MPC885 PowerQUICC Family Reference Manual Rev 2 E 4 Freescale Semiconductor ...
Page 1386: ...Revision History MPC885 PowerQUICC Family Reference Manual Rev 2 I 2 Freescale Semiconductor ...