CHAPTER 14 TROUBLESHOOTING
14-204
COPYRIGHT © 1999 CANON INC. CANON imageRUNNER 400/330 REV.0 JAN. 1999 PRINTED IN JAPAN (IMPRIME AU JAPON)
<BODY>
OPTION
Level 3
GUIDE-SW
PRIAC-SW
ELC-PWR
FAN-SPD
IMG-CLR
FIX-TIPE
Remarks
0*: no control
1: control on 2nd side
of double-sided copy
2: control on all
0*:do not increase
charging current
1: increase charging
current
0*:disable anti-
flickering
mechanism
1: enable anti-flicker
mechanism
0*:disables fan
rotation speed
rotation control.
1: in standby, stops 2
delivery heat
discharge fans.
2: in addition to '1',
rotates 2 delivery
heat discharge fans
at half speed.
0*:factory setting
1: clear print images
at power-on (main
power)
0*:for 120/230-V
model.
1: for 100-V model.
Description
Sets control mode for driving the fixing assembly inlet guide.
Use it if images are soiled along the trailing edge of paper
owing to the fixing assembly. (In such a case, select
descent control.)
Use it to enable or disable image improvement made by
changing the charging current level (as when correcting
image faults caused by charging faults of the drum
cartridge). It will be effective if the image tends to show
white spots in solid areas often occurring between when a
new drum cartridge is mounted and about 2000 copies are
made.
Use it ('1' -> '0') in the following cases:
If a new drum cartridge has been installed and the
copier has been turned on.
If COPIER>FUNCTION>D-GAMMA has been
executed in service mode.
If the setting has been changed for this item.
Enables or disables a mechanism to prevent flickering of
the fluorescent lamp caused by a site environmental factor.
Select this item if the fluorescent lamp flickers because of
the condition of the site.
(effective in 100/120-V areas only)
Selects fan drive sound reduction mode.
Use it to reduce the sound of fan drive by decreasing fan
rotation speed.
This mode is effective only when the site is 27.5°C or less.
Do not use it if the site temperature is 27.5°C or more.
(applicable to FM2, FM3)
Use this mode to enable/disable clearing print images in
the memory on the image processor PCB when the main
power is turned on.
n
Conditions
The machine must be equipped with an image memory
back-up battery.
The printer control software netCraft is used.
n
If the machine is equipped with an image memory
back-up battery, the images are backed up even when
the main power is turned off. However, some
commercially available printer control software is
designed to clear the printer log when the main power is
turned off, requiring the mode to be set to '1'.
Not used.
In a 120/230-V model, fixed to '0'. Do not change the
setting.