ADJUST Items
Level 1
ADJUST
Level 2
LAMP
AE
ADJ-XY
CCD
LASER
DEVELOP
DENS
HV-PRI
HV-TR
FEED-ADJ
CST-ADJ
Level 3
FL-OFST
FL-DUST
FL-PDUTY
AE-TBL
ADJ-X
ADJ-Y
ADJ-S
PPR
W-PLT
PVE-OFST
LA-OFF
DE-DC
DE-NO-DC
DE-OFST
DENS-ADJ
P-DC
P-NO-DC
P-AC
P-NO-AC
AGS-GAIN
AGS-OFST
OFST1-DC
OFST1-AC
OFST2-AC
P-AC2
P-AC3
TR-N1
TR-N2
TR-OFST
TR-SPP
REGIST
LOOP-CST
LOOP-MF
ADJ-REFE
RVS-FD1
RVS-FD2
RVS-DUP
MF-A4R
MF-A6R
MF-A4
Outline
scanning lamp offset
lamp post-activation duty ratio adjustment
lamp pre-activation duty ratio adjustment
AE mode text density adjustment
image read start position (X direction)
adjustment
image read state position (Y direction)
adjustment
standard white plate read start position fine
adjustment
standard white plate density data
standard white plate data
offset from laser center
laser trailing edge deactivation adjustment
developing DC output during image exposure
developing DC output during image exposure
image bias DC component offset
post copy density auto correction fogging
adjustment
image area primary charging DC output
sheet-to-sheet primary charging DC output
primary charging AC output 1 during image
exposure
sheet-to-sheet primary charging DC output
APVC gain
APVC offset
primary charging DC offset
primary charging AC offset 1
primary charging AC offset 2
primary charging AC output 2 during image
exposure
primary charging AC output 3 during image
exposure
transfer roller bias adjustment (1st side)
transfer roller bias adjustment (2nd side)
transfer charging offset
thick paper ATVC table offset adjustment
registration clutch ON timing
cassette pick-up arching adjustment
multifeeder arching adjustment
re-pick up horizontal registration adjustment
1-bin reversal point adjustment
2-/3-bin reversal point adjustment
duplexing reversal pin adjustment
multifeeder paper width sensor adjustment
(A4R)
multifeeder paper width sensor adjustment
(A6R)
multifeeder paper width sensor adjustment
(A4)
Range
0 to 255
0 to 100
0 to 100
0 to 9
0 to 1000
0 to 400
50 to 80
0 to 255
0 to 255
-200 to +200
0 to 255
0 to 127
0 to 127
98 to 158
0 to 9
0 to 127
0 to 127
0 to 127
0 to 127
78 to 178
78 to 178
98 to 158
98 to 158
98 to 158
0 to 255
0 to 255
0 to 10
0 to 10
98 to 158
0 to 10
-320 to +320
0 to 200
0 to 200
7500 to 8500
factory setting±100
factory setting±100
factory setting±100
0 to 1000
0 to 1000
0 to 1000