CHAPTER 7 PICK-UP/FEEDING SYSTEM
7-56
COPYRIGHT © 1999 CANON INC. CANON imageRUNNER 400/330 REV.0 JAN. 1999 PRINTED IN JAPAN (IMPRIME AU JAPON)
2. Removing the Multifeeder Pick-Up
Roller
1) Pull out the roll [1] of the multifeeder
cover.
2) Free the cable from the hook [3]; then,
detach the right door [2].
Figure 7-217
Figure 7-216
3) Remove the snap-on bushing [2], and shift
the roller shaft [3] in the direction of the
arrow.
4) Remove the stop shaft [4], and remove the
multifeeder pick-up roller [5].
Caution:
1. Take care not to drop the pin fitted at
the rear of the multifeeder pick-up
roller.
2. Take care not to deform the
grounding plate found at the rear of
the roller shaft.
3. Removing the Separation Pad
1) Remove the right door.
2) Remove the multifeeder pick-up roller.
3) While pushing the end [1] of the right
door in the direction of A, move the rear
of the separation pad cover [2] in the
direction of B to remove.
Figure 7-218
4) Free the hook [4] of the lever [3], and
move it in the direction of the arrow to
remove.
Figure 7-219
5) Remove the multifeeder holding plate
retaining plate [5], and detach the
separation pad [6].
Figure 7-219-1
[1]
[3]
[2]
Roll
[2]
[3]
[4]
[5]
[2]
[1]
B
A
[3]
[4]
[5]
[5]
[6]