COPYRIGHT © 1999 CANON INC. CANON imageRUNNER 400/330 REV.0 JAN. 1999 PRINTED IN JAPAN (IMPRIME AU JAPON)
14-63
CHAPTER 14 TROUBLESHOOTING
7
E014 (The fixing motor fails to rotate normally.)
Cause
Connector
DC controller
PCB
Fixing motor
Fixing cleaning
belt
Composite power
supply PCB
Harness
DC controller
PCB, Image
processor PCB
Action
Connect the connector.
Replace the DC
controller PCB.
Replace the fixing motor
PCB.
Replace the fixing
cleaning belt. Clear the
counter reading.
Replace the composite
power supply PCB.
Replace the harness.
Replace the DC
controller PCB and the
image processor PCB.
Step
1
2
3
4
5
6
Yes/No
YES
NO
NO
YES
NO
NO
YES
Check
Is J115 on the DC controller PCB
disconnected?
Does the voltage of J115-A7
(M2D) on the DC controller PCB
change from about 5 to about 0
VDC while the fixing motor is
rotating?
Does the voltage on J115-A6
(M2LCK) on the DC controller
PCB change from about 5 to about
0 VDC while the fixing motor is
rotating?
Is the fixing cleaning belt taken up
correctly?
Is 24 VDC present between J204-7
and -8 on the composite power
supply PCB?
Is the continuity of the harness
between the image processor PCB
and the DC controller PCB normal?
J714-A14 and J113-A7
J714-A16 and J113-A5