COPYRIGHT © 1999 CANON INC. CANON imageRUNNER 400/330 REV.0 JAN. 1999 PRINTED IN JAPAN (IMPRIME AU JAPON)
14-27
CHAPTER 14 TROUBLESHOOTING
n
If PD-ME/DZ-ME Is NG
1. Clean the scanner.
2. Isolate the problem.
Execute toner stirring
COPIER>FUNCTION>INSTALL>
TONER-S
Execute drum resistance measurement COPIER>FUNCTION>DPC>
D-GAMMA
A this time, take notes of the measurement of D-GAMMA.
3. Execute copy density correction once again.
If the result is still NG, perform the following according to the measurement of D-GAMMA.
If 2.3 or higher, replace the drum cartridge.
If 0.1 or lower, replace the developing assembly.