COPYRIGHT © 1999 CANON INC. CANON imageRUNNER 400/330 REV.0 JAN. 1999 PRINTED IN JAPAN (IMPRIME AU JAPON)
14-37
CHAPTER 14 TROUBLESHOOTING
C. Troubleshooting Image Faults
1
The copy is too light (halftone area only).
Cause
AE adjustment
Developing
assembly
Developing
assembly
Scanner
Photosensitive
drum
Action
End.
Execute AE adjustment.
Decrease the setting of
COPIER>ADJUST>AE>AE-
TBL.
Check the developing
assembly locking lever,
and check the surface of
the developing assembly
rolls for foreign mater
(e.g., toner).
Check the developing
assembly.
End.
Replace the drum unit.
Step
1
2
3
4
5
6
Yes/No
YES
YES
NO
NO
YES
NO
Check
Perform the Image Adjustment
Basic Procedure. Is the problem
corrected?
Be sure that the pattern print is
correctly placed when executing
FUNCTION>DENS>PD-ME, DZ-
ME.
Make a copy in AE mode. Is the
text too light?
Are the rolls of the developing
assembly in firm contact with the
drum?
Is the surface of the developing
cylinder coated with an even layer
of toner?
Clean the mirror, lens, and dust-
proofing glass. Is the problem
corrected?