COPYRIGHT © 1999 CANON INC. CANON imageRUNNER 400/330 REV.0 JAN. 1999 PRINTED IN JAPAN (IMPRIME AU JAPON)
14-95
CHAPTER 14 TROUBLESHOOTING
44 The scanner fails to move forward/in reverse.
Cause
Scanner drive
cable
Scanner path
Connector
Scanner motor
(M3)
DC controller
PCB
Action
Correct the routing.
Check the scanner rail
for dirt, foreign matter,
and any other which
may come into contact
with the scanner.
Correct the wiring/
connection.
End.
Replace the DC
controller PCB.
Step
1
2
3
4
Yes/No
NO
YES
NO
YES
NO
Check
Is the scanner drive cable routed
correctly?
Is the scanner rail free of dirt, and
does the scanner move smoothly?
Is the wiring/connection from the
connector J116 on the DC
controller PCB to the scanner
motor through the relay connector
J28 normal?
Replace the scanner motor. Is the
problem corrected?
45 The pre-exposure lamp fails to turn on.
Cause
Pre-exposure
lamp
DC controller
PCB
Action
End.
Replace the DC
controller PCB.
Step
1
Yes/No
YES
NO
Check
Does the setting of I/O>DC-
CON>P005-bit1 change from ''0' to
'1' as soon as the pre-exposure lamp
turns on? (J112-A2: PED) The
resistance of the pre-exposure lamp
is about 25 to 30
Ω