CHAPTER 14 TROUBLESHOOTING
14-88
COPYRIGHT © 1999 CANON INC. CANON imageRUNNER 400/330 REV.0 JAN. 1999 PRINTED IN JAPAN (IMPRIME AU JAPON)
37 E805 (The fan rotation is faulty.)
Cause
Connector
DC controller
PCB
Fan
Action
End.
Correct the connection.
Replace the DC
controller PCB.
Replace the fan
Step
1
2
3
Yes/No
YES
NO
NO
YES
Check
Turn off and then on the main
power. Is the problem corrected?
Check the details of the error
history in service mode (Table 10-
201). If no detail code is indicated,
suspect the feeder fan (FM1) or the
reversing guide cooling fan (FM9).
Is the connection of these fans
normal?
If a detail code is indicated, is the
connection of the indicated fan
good?
Is the drive signal of the fan
identified in the previous step about
22 VDC while the fan is rotating or
about 12 VDC otherwise?
Notation
FM2
FM3
FM4
FM5
FM6
FM7
FM8
FM10
FM11
FM12
FM13
FM14
FM15
FM16
FM17
FM18
I/O>DC-CON>P011
bit0
bit1
bit2
bit3
bit7
bit4
bit5
bit11
bit12
bit13
bit14
bit8
bit9
bit10
bit6
bit15
Detail code
0002
0003
0004
0005
0006
0007
0008
0010
0011
0012
0013
0014
0015
0016
0017
0018
Jack number
J107-A5
J107-A8
J112-B8
J112-A8
J112-A11
J112-B14
J112-B17
J118-2
J107-A5
J104-A6
J04-A9
J107-A5
J107-A8
J119-8
J112-B11
J104-A12
Normal rotation signal
FM2LK
FM3LK
FM4LK
FM5LK
FM6LK
FM7LK
FM8LK
FM10LK
FM11LK
FM12LK
FM13LK
FM14LK
FM15LK
FM16LK
FM17LK
FM18LK