CHAPTER 6 IMAGE FORMATION SYSTEM
6-10
COPYRIGHT © 1999 CANON INC. CANON imageRUNNER 400/330 REV.0 JAN. 1999 PRINTED IN JAPAN (IMPRIME AU JAPON)
4. Correcting the Application Voltage Level (ATVC control)
The transfer charging efficiency varied according to changes in humidity or deterioration of the
transfer roller. A reference current is applied each time the Copy Start key is pressed to measure the
degree of voltage output for correction as follows:
A reference current is applied during initial rotation after the Copy Start key is pressed.
The transfer voltage is detected and returned to the PW-CPU on the composite power supply
PCB.
The PW-CPU computes an optimum application voltage.
Transfer charging is started using the optimum application voltage.