CHAPTER 14 TROUBLESHOOTING
14-62
COPYRIGHT © 1999 CANON INC. CANON imageRUNNER 400/330 REV.0 JAN. 1999 PRINTED IN JAPAN (IMPRIME AU JAPON)
6
E010 (The main motor fails to rotate normally.)
Cause
Harness, Wiring
Main motor
Composite power
supply PCB
DC controller
PCB
Harness
DC controller
PCB, Image
processor PCB
Action
Go to step 5.
Correct the wiring.
Replace the main motor
(main motor driver
PCB).
Replace the composite
power supply PCB.
Replace the DC
controller PCB.
Replace the harness.
Replace the DC
controller PCB and the
image processor PCB.
Step
1
2
3
4
5
6
7
Yes/No
NO
NO
NO
NO
NO
YES
YES
Check
Does the main motor rotate until
E010 turns on?
Are the connectors and wiring
around the main motor normal?
Does the voltage of J102-B12
(M1LCK) on the DC controller
PCB change to 0 VDC while the
main motor is rotating?
Is 24 VDC generated between
J204-3 and -4 on the composite
power supply PCB?
Is the voltage of J102-B11 on the
DC controller PCB about 5 VDC
during WMUP? (normal if 5 V
during rotation)
Is the continuity of the harness
between the image processor PCB
and the DC controller PCB normal?
J714-A14 to J113-A7
J714-A16 to J113-A5