CHAPTER 14 TROUBLESHOOTING
3
Mounting the Scanning Lamp
Keep the following in mind when
mounting the scanning lamp:
1. Orient it so that the side (terminal) with
the manufacturer's name is toward the
rear.
2. Orient it so that its transparent side is
toward the reflecting plate.
3. Do not touch the transparent side.
Figure 14-213
Make the following adjustments when
replacing the scanning lamp:
1) Shading correction 2
FUNCTION>CCD>
MAN-ADJ
2) Auto density correction
FUNCTION>DENS>
WHITE-ME
PD-DENS
PD-ME
DZ-DENS
DZ-ME
For details, see the description for
FUCNTION in service mode (VIII. of Chapter
14).
Transparent side
Reflecting plate
C. Image Formation System
1
When Replacing the Drum Unit
Record the date and the counter reading
on the label, and attach it to the front cover
of the new drum unit.
Clean the fixing separation claw (upper,
lower).
œ t
date
date Datum
ı l
notes
note Notiz
J E
^ [
J E
^ [
counter
compteur Zähler