CHAPTER 5 LASER EXPOSURE SYSTEM
5-4
COPYRIGHT © 1999 CANON INC. CANON imageRUNNER 400/330 REV.0 JAN. 1999 PRINTED IN JAPAN (IMPRIME AU JAPON)
The flow of signals is as shown in Figure 5201. The image processor PCB generates clock
signals for synchronized control using the BD signal. The image signals from the CCD is written to
the memory for horizontal synchronization, and the image signals are read in conjunction with the
clock signals for transfer to the laser driver PCB.
Figure 5-201
Related Service Mode
E100
The BD signal is not detected within 2 sec after the laser beam is turned
on. (laser emission start signal)
The synchronization of the BD signal has an irregularity.
Image processor PCB
Laser driver PCB
BD detection PCB
CCD PCB
Memory for horizontal
synchronization
(main scanning direction)
Clock signal generation for
horizontal synchronization
BD signal
Image signal
Image signal
J708
J717B
PBD
J500B
J500A
J717A
J510
J706
J301
8
8