CHAPTER 9 FIXING SYSTEM
9-22
COPYRIGHT © 1999 CANON INC. CANON imageRUNNER 400/330 REV.0 JAN. 1999 PRINTED IN JAPAN (IMPRIME AU JAPON)
5. Removing the Upper Separation
Claw
1) Open the front door.
2) Open the delivery assembly.
3) Remove the fixing assembly.
4) Remove the separation claw unit. (See 5
"Removing the Lower Separation Claw.")
5) Remove the two screws, and detach the
upper separation unit [2]; then, detach the
five upper separation claws [4] while
paying attention to the spring [3] (1 each).
Figure 9-225
6. Position of the Fixing Assembly
Inlet Guide
The fixing assembly inlet guide is
adjusted in connection with the inlet guide
mount. As such, its position need not be
adjusted if the inlet guide is mounted.
Caution:
If you detached the inlet guide mount,
you would have to adjust the position of
the inlet guide. Do not loosen the screw
on the inlet guide. If you must, be sure to
mark the position with a scriber.
[7]
[6]
[8]
[9]