SINAMICS G130/G150
List Manual (LH2), 07/2016, A5E03263479A
955
2 Parameters
2.2 List of parameters
Dependency:
Refer to: p9556
Note:
The shutdown speed has no effect for a value = 0.
SS1: Safe Stop 1
Description:
Sets the stop response for the function "Safely Limited Speed" (SLS).
This setting applies for all SLS limit values.
An input value of less than 5 signifies personnel protection, from 10 and upwards, machine protection.
This parameter can only be used for SINUMERIK Safety Integrated.
For motion monitoring functions integrated in the drive, only a value of 5 is permissible. Other settings result in the
safety message C01711/C30711 with message value 44.
Value:
0:
STOP A
1:
STOP B
2:
STOP C
3:
STOP D
4:
STOP E
5:
Sets the stop response via p9563 (SLS-specific)
10:
STOP A with delayed STO when the bus fails
11:
STOP B with delayed STO when the bus fails
12:
STOP C with delayed STO when the bus fails
13:
STOP D with delayed STO when the bus fails
14:
STOP E with delayed STO when the bus fails
Dependency:
Refer to: p9531, p9563, p9580
Note:
SLS: Safely Limited Speed / SG: Safely reduced speed
Description:
Sets the stop response for the function "Safely Limited Position" (SLP).
Value:
0:
STOP A
1:
STOP B
2:
STOP C
3:
STOP D
4:
STOP E
10:
STOP A with delayed stop response when the bus fails
11:
STOP B with delayed stop response when the bus fails
12:
STOP C with delayed stop response when the bus fails
13:
STOP D with delayed stop response when the bus fails
14:
STOP E with delayed stop response when the bus fails
Index:
[0] = Limit value SLP1 (SE1)
[1] = Limit value SLP2 (SE2)
Dependency:
Refer to: p9534, p9535
Note:
In the extended sense, a bus failure should be seen here as a communication error in the control signals of the safety
functions (e.g. via PROFIsafe or TM54F).
SLP: Safely Limited Position / SE: Safe software limit switches
p9561
SI Motion SLS (SG) stop response (Control Unit) / SI Mtn SLS resp
VECTOR_G
Can be changed:
U, T
Calculated:
-
Access level:
4
Data type:
Integer16
Dyn. index:
-
Func. diagram:
-
P-Group:
Safety Integrated
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0 14
5
p9562[0...1]
SI Motion SLP (SE) stop response (Control Unit) / SI Mtn SLP Stop CU
VECTOR_G
Can be changed:
C2(95)
Calculated:
-
Access level:
3
Data type:
Integer16
Dyn. index:
-
Func. diagram:
-
P-Group:
Safety Integrated
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0 14
2
Содержание SINAMICS G130
Страница 1: ...s SINAMICS SINAMICS G130 G150 List Manual 07 2016 Edition ...
Страница 2: ......
Страница 8: ...Preface SINAMICS G130 G150 8 List Manual LH2 07 2016 A5E03263479A ...
Страница 1940: ...4 Faults and alarms 4 2 List of faults and alarms SINAMICS G130 G150 1940 List Manual LH2 07 2016 A5E03263479A ...
Страница 1960: ...A Appendix A 3 References SINAMICS G130 G150 1960 List Manual LH2 07 2016 A5E03263479A ...
Страница 1974: ...Index SINAMICS G130 G150 1974 List Manual LH2 07 2016 A5E03263479A ...
Страница 1975: ......