SINAMICS G130/G150
List Manual (LH2), 07/2016, A5E03263479A
257
2 Parameters
2.2 List of parameters
Description:
Sets the signal source for terminal DI/DO 8 (X122.9 / X121.7).
Regarding the terminal designation:
The first designation is valid for CU320, the second for CU310.
Notice:
The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
Note:
Prerequisite: The DI/DO must be set as an output (p0728.8 = 1).
DI/DO: Bidirectional Digital Input/Output
Description:
Sets the signal source for terminal DI/DO 9 (X122.10 / X121.8).
Regarding the terminal designation:
The first designation is valid for CU320, the second for CU310.
Notice:
The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
Note:
Prerequisite: The DI/DO must be set as an output (p0728.9 = 1).
DI/DO: Bidirectional Digital Input/Output
Description:
Sets the signal source for terminal DI/DO 10 (X122.12 / X121.10).
Regarding the terminal designation:
The first designation is valid for CU320, the second for CU310.
Notice:
The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
Note:
Prerequisite: The DI/DO must be set as an output (p0728.10 = 1).
DI/DO: Bidirectional Digital Input/Output
Description:
Sets the signal source for terminal DI/DO 11 (X122.13 / X121.11).
Regarding the terminal designation:
The first designation is valid for CU320, the second for CU310.
p0738
BI: CU signal source for terminal DI/DO 8 / CU S_src DI/DO 8
CU_G130_PN,
CU_G150_PN,
CU_G130_DP,
CU_G150_DP
Can be changed:
U, T
Calculated:
-
Access level:
1
Data type:
Unsigned32 / Binary
Dyn. index:
-
Func. diagram:
2119, 2130
P-Group:
Commands
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- -
0
p0739
BI: CU signal source for terminal DI/DO 9 / CU S_src DI/DO 9
CU_G130_PN,
CU_G150_PN,
CU_G130_DP,
CU_G150_DP
Can be changed:
U, T
Calculated:
-
Access level:
1
Data type:
Unsigned32 / Binary
Dyn. index:
-
Func. diagram:
2130
P-Group:
Commands
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- -
0
p0740
BI: CU signal source for terminal DI/DO 10 / CU S_src DI/DO 10
CU_G130_PN,
CU_G150_PN,
CU_G130_DP,
CU_G150_DP
Can be changed:
U, T
Calculated:
-
Access level:
1
Data type:
Unsigned32 / Binary
Dyn. index:
-
Func. diagram:
2131
P-Group:
Commands
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- -
0
p0741
BI: CU signal source for terminal DI/DO 11 / CU S_src DI/DO 11
CU_G130_PN,
CU_G150_PN,
CU_G130_DP,
CU_G150_DP
Can be changed:
U, T
Calculated:
-
Access level:
1
Data type:
Unsigned32 / Binary
Dyn. index:
-
Func. diagram:
2119, 2131
P-Group:
Commands
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- -
0
Содержание SINAMICS G130
Страница 1: ...s SINAMICS SINAMICS G130 G150 List Manual 07 2016 Edition ...
Страница 2: ......
Страница 8: ...Preface SINAMICS G130 G150 8 List Manual LH2 07 2016 A5E03263479A ...
Страница 1940: ...4 Faults and alarms 4 2 List of faults and alarms SINAMICS G130 G150 1940 List Manual LH2 07 2016 A5E03263479A ...
Страница 1960: ...A Appendix A 3 References SINAMICS G130 G150 1960 List Manual LH2 07 2016 A5E03263479A ...
Страница 1974: ...Index SINAMICS G130 G150 1974 List Manual LH2 07 2016 A5E03263479A ...
Страница 1975: ......