2 Parameters
2.2 List of parameters
SINAMICS G130/G150
100
List Manual (LH2), 07/2016, A5E03263479A
Description:
Displays the firmware version of the Voltage Sensing Module (VSM).
Dependency:
Refer to: r0018, r0128, r0197, r0198
Note:
Example:
The value 1010100 should be interpreted as V01.01.01.00.
Description:
Displays the firmware version of the Terminal Module.
Dependency:
Refer to: r0018, r0128, r0148, r0197, r0198
Note:
Example:
The value 1010100 should be interpreted as V01.01.01.00.
Description:
Displays the firmware version of the DRIVE-CLiQ Hub Module.
Description:
Sets the component number for the option board (e.g. Terminal Board 30).
This unique component number is assigned when parameterizing the topology.
Only component numbers can be entered into this parameter that correspond to an option board.
r0158[0...n]
Voltage Sensing Module firmware version / VSM FW version
VECTOR_G
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Unsigned32
Dyn. index:
p0150
Func. diagram:
-
P-Group:
Encoder
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- -
-
r0158
Terminal Module firmware version / TM FW version
TM31, TM120, TM150,
TM54F_MA,
TM54F_SL
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Unsigned32
Dyn. index:
-
Func. diagram:
-
P-Group:
Terminals
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- -
-
r0158
DRIVE-CLiQ Hub Module firmware version / Hub FW version
HUB
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Unsigned32
Dyn. index:
-
Func. diagram:
-
P-Group:
Terminals
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- -
-
p0161
Option board component number / Opt board comp_no
TB30
Can be changed:
C1(4)
Calculated:
-
Access level:
4
Data type:
Unsigned8
Dyn. index:
-
Func. diagram:
-
P-Group:
Data sets
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0 199
0
Содержание SINAMICS G130
Страница 1: ...s SINAMICS SINAMICS G130 G150 List Manual 07 2016 Edition ...
Страница 2: ......
Страница 8: ...Preface SINAMICS G130 G150 8 List Manual LH2 07 2016 A5E03263479A ...
Страница 1940: ...4 Faults and alarms 4 2 List of faults and alarms SINAMICS G130 G150 1940 List Manual LH2 07 2016 A5E03263479A ...
Страница 1960: ...A Appendix A 3 References SINAMICS G130 G150 1960 List Manual LH2 07 2016 A5E03263479A ...
Страница 1974: ...Index SINAMICS G130 G150 1974 List Manual LH2 07 2016 A5E03263479A ...
Страница 1975: ......