2 Parameters
2.2 List of parameters
Description:
Setting of the tolerance window for the sign of life monitoring for communication to the power unit.
Dependency:
Refer to: A30853
Note:
An active window is generated by means of DRIVE-CLiQ telegrams.
If more than one sign-of-life error appears in the window, then A30853 is output.
The lower the value in p7788, the greater the monitoring tolerance.
Description:
Sets the number of consecutive sign-of-life errors that are tolerated for communication to the power unit.
Dependency:
Refer to: F30008
Note:
F30008 is output in the case of a fault.
The higher the value in the parameter, the higher the monitoring tolerance.
Description:
Sets the individual signals for the component trace.
For p7790[0...15] = 0, the component trace is deactivated.
For index 0 ... 7:
The signals are set in p7790[0...7], whose characteristic is to be recorded over time.
If "No signal" is set for a trace channel, then the recording duration of the other time characteristics is increased.
For index 8 ... 15:
The signals are set in p7790[8...15], whose instantaneous value is to be recorded.
Value:
0:
No signal
1:
Pulse frequency
2:
Phase current U
3:
Phase current V
p7788
Power unit sign-of-life monitoring tolerance window / PU SoL monit tol
VECTOR_G, B_INF
Can be changed:
U, T
Calculated:
-
Access level:
4
Data type:
Unsigned16
Dyn. index:
-
Func. diagram:
-
P-Group:
Converter
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
1 1000
10
p7789
Power unit sign-of-life monitoring fault threshold / PU SoL monit F_thr
VECTOR_G, B_INF
Can be changed:
U, T
Calculated:
-
Access level:
4
Data type:
Unsigned16
Dyn. index:
-
Func. diagram:
-
P-Group:
Converter
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0 1000
1
p7790[0...15]
Component trace signal / Comp trace sig
VECTOR_G, B_INF
Can be changed:
U, T
Calculated:
-
Access level:
4
Data type:
Integer16
Dyn. index:
-
Func. diagram:
-
P-Group:
Converter
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0 9
[0]
2
[1] 3
[2] 4
[3] 7
[4] 8
[5] 9
[6] 5
[7] 0
[8] 6
[9] 1
[10...15] 0
Содержание SINAMICS G130
Страница 1: ...s SINAMICS SINAMICS G130 G150 List Manual 07 2016 Edition ...
Страница 2: ......
Страница 8: ...Preface SINAMICS G130 G150 8 List Manual LH2 07 2016 A5E03263479A ...
Страница 1940: ...4 Faults and alarms 4 2 List of faults and alarms SINAMICS G130 G150 1940 List Manual LH2 07 2016 A5E03263479A ...
Страница 1960: ...A Appendix A 3 References SINAMICS G130 G150 1960 List Manual LH2 07 2016 A5E03263479A ...
Страница 1974: ...Index SINAMICS G130 G150 1974 List Manual LH2 07 2016 A5E03263479A ...
Страница 1975: ......