2 Parameters
2.2 List of parameters
SINAMICS G130/G150
976
List Manual (LH2), 07/2016, A5E03263479A
For index 1:
The display of the load-side position actual value on the second channel is updated in the CDC clock cycle (r9724)
and delayed by one CDC clock cycle.
For index 2:
The difference between the load-side position actual value on the Control Unit and load-side position actual value in
the second channel is updated in the CDC clock cycle (r9724) and delayed by one CDC clock cycle.
For index 3:
The maximum difference between the load-side position actual value on the Control Unit and the load-side position
actual value on the second channel.
For index 4:
Displays the load-side position actual value when enabling the function "Safe position via PROFIsafe".
The value is an average value from the values in index 0 and 1.
When the function is not enabled, the content corresponds to the value in index 0.
For index 5:
The display of the maximum additional difference between the load-side position actual value on the Control Unit,
and the load-side position actual value in the second channel, which can occur as a result of the actual value sensing
delay in the EnDat 2.2 converter.
Input in p9542: p9708[3] + p9708[5], after performing the measurement for the mechanical tolerance by performing a
test run, where, after completion, the maximum tolerance that has occurred is displayed in p9708[3].
CDC: Crosswise Data Comparison
Description:
Displays result list 1 that, for the crosswise data comparison between the monitoring channels, led to the fault.
Index:
[0] = Result list second channel
[1] = Result list drive
Dependency:
Refer to: C01711
Note:
SBR: Safe Brake Ramp (safe brake ramp monitoring)
SLP: Safely Limited Position
SLS: Safely Limited Speed
SOS: Safe Operating Stop
r9710[0...1]
SI Motion diagnostics result list 1 / SI Mtn res_list 1
VECTOR_G
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Unsigned32
Dyn. index:
-
Func. diagram:
-
P-Group:
Safety Integrated
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- -
-
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
Actual value > upper limit SOS
Yes
No
-
01
Actual value > lower limit SOS
Yes
No
-
02
Actual value > upper limit SLP1
Yes
No
-
03
Actual value > lower limit SLP1
Yes
No
-
04
Actual value > upper limit SLP2
Yes
No
-
05
Actual value > lower limit SLP2
Yes
No
-
06
Actual value > upper limit SLS1
Yes
No
-
07
Actual value > lower limit SLS1
Yes
No
-
08
Actual value > upper limit SLS2
Yes
No
-
09
Actual value > lower limit SLS2
Yes
No
-
10
Actual value > upper limit SLS3
Yes
No
-
11
Actual value > lower limit SLS3
Yes
No
-
12
Actual value > upper limit SLS4
Yes
No
-
13
Actual value > lower limit SLS4
Yes
No
-
16
Actual value > upper limit SAM/SBR
Yes
No
-
17
Actual value > lower limit SAM/SBR
Yes
No
-
18
Actual value > upper limit SDI positive
Yes
No
-
19
Actual value > lower limit SDI positive
Yes
No
-
20
Actual value > upper limit SDI negative
Yes
No
-
21
Actual value > lower limit SDI negative
Yes
No
-
Содержание SINAMICS G130
Страница 1: ...s SINAMICS SINAMICS G130 G150 List Manual 07 2016 Edition ...
Страница 2: ......
Страница 8: ...Preface SINAMICS G130 G150 8 List Manual LH2 07 2016 A5E03263479A ...
Страница 1940: ...4 Faults and alarms 4 2 List of faults and alarms SINAMICS G130 G150 1940 List Manual LH2 07 2016 A5E03263479A ...
Страница 1960: ...A Appendix A 3 References SINAMICS G130 G150 1960 List Manual LH2 07 2016 A5E03263479A ...
Страница 1974: ...Index SINAMICS G130 G150 1974 List Manual LH2 07 2016 A5E03263479A ...
Страница 1975: ......