2 Parameters
2.2 List of parameters
SINAMICS G130/G150
96
List Manual (LH2), 07/2016, A5E03263479A
Description:
Setting to activate/deactivate an encoder interface (Sensor Module).
Value:
0:
Deactivate component
1:
Activate component
2:
Component deactivate and not present
Recommendation:
After inserting a component, before activating, first wait for Alarm A01317.
Dependency:
Refer to: r0146
Refer to: A01314, A01317
Note:
The deactivation of an encoder interface corresponds to the"parking encoder" function and has the same effect.
The activation of a component can be rejected if the component was inserted for the first time.
In this case, it is only possible to activate the component when the pulses for all of the drive objects are inhibited.
With the encoder interface for encoder 1 (motor encoder), the relevant drive object for writing the parameter must be
in the "Ready for operation" state.
With the encoder interface for encoders 2 and 3, the parameter can also be written during operation.
For value = 0, 2:
When a component is deactivated it no longer outputs any errors.
If value = 0:
The component was completely commissioned and is deactivated using this value. It can be removed from the
DRIVE-CLiQ without any error.
If value = 1:
The component must be available for error-free operation.
If value = 2:
A component in a project generated offline and set to this value must never be inserted in the actual topology from
the very start.
For components that comprise several individual components (e.g. Double Motor Modules), it is not permissible to
set just one subset to this value.
Description:
Displays the "active" or "inactive" state of an encoder interface (Sensor Module).
Value:
0:
Component inactive
1:
Component active
Dependency:
Refer to: p0105, p0145, p0480, p0897
Description:
Displays the version of the EEPROM data of the Sensor Module.
Dependency:
Refer to: r0127, r0157
p0145[0...n]
Activate/deactivate encoder interface / Enc_intf act/deact
VECTOR_G, ENC
Can be changed:
C1(4), U, T
Calculated:
-
Access level:
2
Data type:
Integer16
Dyn. index:
EDS, p0140
Func. diagram:
-
P-Group:
Data sets
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0 2
1
r0146[0...n]
Encoder interface active/inactive / Enc_intf act/inact
VECTOR_G, ENC
Can be changed:
-
Calculated:
-
Access level:
2
Data type:
Integer16
Dyn. index:
EDS, p0140
Func. diagram:
-
P-Group:
Data sets
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0 1
-
r0147[0...n]
Sensor Module EEPROM data version / SM EEPROM version
VECTOR_G, ENC
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Unsigned32
Dyn. index:
EDS, p0140
Func. diagram:
-
P-Group:
Encoder
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- -
-
Содержание SINAMICS G130
Страница 1: ...s SINAMICS SINAMICS G130 G150 List Manual 07 2016 Edition ...
Страница 2: ......
Страница 8: ...Preface SINAMICS G130 G150 8 List Manual LH2 07 2016 A5E03263479A ...
Страница 1940: ...4 Faults and alarms 4 2 List of faults and alarms SINAMICS G130 G150 1940 List Manual LH2 07 2016 A5E03263479A ...
Страница 1960: ...A Appendix A 3 References SINAMICS G130 G150 1960 List Manual LH2 07 2016 A5E03263479A ...
Страница 1974: ...Index SINAMICS G130 G150 1974 List Manual LH2 07 2016 A5E03263479A ...
Страница 1975: ......