2 Parameters
2.2 List of parameters
SINAMICS G130/G150
664
List Manual (LH2), 07/2016, A5E03263479A
Description:
Sets the setpoint for the input signals in the simulation mode of the digital inputs of the Terminal Board 30 (TB30).
Dependency:
The simulation of a digital input is selected using p4095.
Refer to: p4095
Note:
This parameter is not saved when data is backed-up (p0971, p0977).
DI: Digital Input
Description:
Sets the simulation mode for the analog inputs of Terminal Module 31 (TM31).
Value:
0:
Terminal evaluation for analog input x
1:
Simulation for analog input x
Index:
[0] = AI 0 (X521.1/X521.2, S5.0)
[1] = AI 1 (X521.3/X521.4, S5.1)
Dependency:
The setpoint for the input voltage is specified via p4098.
Refer to: p4098
Note:
This parameter is not saved when data is backed-up (p0971, p0977).
AI: Analog Input
Description:
Sets the simulation mode for the analog inputs of the Terminal Board 30 (TB30).
Value:
0:
Terminal evaluation for analog input x
1:
Simulation for analog input x
Index:
[0] = AI 0 (X482.1/X482.2)
[1] = AI 1 (X482.3/X482.4)
Dependency:
The setpoint for the input voltage is specified via p4098.
Refer to: p4098
Note:
This parameter is not saved when data is backed-up (p0971, p0977).
AI: Analog Input
p4096
TB30 digital inputs simulation mode setpoint / TB30 DI sim setpt
TB30
Can be changed:
U, T
Calculated:
-
Access level:
2
Data type:
Unsigned32
Dyn. index:
-
Func. diagram:
9099, 9100
P-Group:
Commands
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- -
0000
bin
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
DI 0 (X481.1)
High
Low
-
01
DI 1 (X481.2)
High
Low
-
02
DI 2 (X481.3)
High
Low
-
03
DI 3 (X481.4)
High
Low
-
p4097[0...1]
TM31 analog inputs simulation mode / TM31 AI sim_mode
TM31
Can be changed:
U, T
Calculated:
-
Access level:
2
Data type:
Integer16
Dyn. index:
-
Func. diagram:
9566, 9568
P-Group:
Terminals
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0 1
0
p4097[0...1]
TB30 analog inputs simulation mode / TB30 AI sim_mode
TB30
Can be changed:
U, T
Calculated:
-
Access level:
2
Data type:
Integer16
Dyn. index:
-
Func. diagram:
9104
P-Group:
Terminals
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0 1
0
Содержание SINAMICS G130
Страница 1: ...s SINAMICS SINAMICS G130 G150 List Manual 07 2016 Edition ...
Страница 2: ......
Страница 8: ...Preface SINAMICS G130 G150 8 List Manual LH2 07 2016 A5E03263479A ...
Страница 1940: ...4 Faults and alarms 4 2 List of faults and alarms SINAMICS G130 G150 1940 List Manual LH2 07 2016 A5E03263479A ...
Страница 1960: ...A Appendix A 3 References SINAMICS G130 G150 1960 List Manual LH2 07 2016 A5E03263479A ...
Страница 1974: ...Index SINAMICS G130 G150 1974 List Manual LH2 07 2016 A5E03263479A ...
Страница 1975: ......