2 Parameters
2.2 List of parameters
SINAMICS G130/G150
110
List Manual (LH2), 07/2016, A5E03263479A
Dependency:
Refer to: F07815
Note:
The parameter is used to identify when the drive is being commissioned for the first time.
The power unit commissioning can only be exited (p0201 = r0200), if the actual and acknowledged code numbers are
identical (p0010 = 2).
For parallel circuit configurations, the parameter index is assigned to a power unit.
Description:
Displays the name of the firmware package on the memory card/device memory.
r0203[0]: Name character 1
...
r0203[15]: Name character 16
For the commissioning software, the ASCII characters are displayed uncoded.
Notice:
An ASCII table (excerpt) can be found, for example, in the appendix to the List Manual.
Description:
Displays the type of power unit found.
Value:
2:
MICROMASTER 440
3:
MICROMASTER 411
4:
MICROMASTER 410
5:
MICROMASTER 436
6:
MICROMASTER 440 PX
7:
MICROMASTER 430
100:
SINAMICS S
101:
SINAMICS S (value)
102:
SINAMICS S (combi)
103:
SINAMICS S120M (distributed)
112:
PM220 (SINAMICS G120)
113:
PM230 (SINAMICS G120)
114:
PM240 (SINAMICS G120)
115:
PM250 (SINAMICS G120 / S120)
116:
PM260 (SINAMICS G120)
118:
SINAMICS G120 Px
120:
PM340 (SINAMICS S120)
126:
SINAMICS ET200PRO
130:
PM250D (SINAMICS G120D)
133:
SINAMICS G120C
135:
SINAMICS PMV40
136:
SINAMICS PMV60
137:
SINAMICS PMV80
138:
SINAMICS G110M
150:
SINAMICS G
151:
PM330 (SINAMICS G120)
200:
SINAMICS GM
250:
SINAMICS SM
260:
SINAMICS MC
300:
SINAMICS GL
r0203[0...15]
Firmware package name / FW pkg name
CU_G130_PN,
CU_G150_PN,
CU_G130_DP,
CU_G150_DP
Can be changed:
-
Calculated:
-
Access level:
4
Data type:
Unsigned8
Dyn. index:
-
Func. diagram:
-
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- -
-
r0203[0...n]
Actual power unit type / PU actual type
VECTOR_G, B_INF
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Integer16
Dyn. index:
PDS, p0120
Func. diagram:
-
P-Group:
Converter
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
2 400
-
Содержание SINAMICS G130
Страница 1: ...s SINAMICS SINAMICS G130 G150 List Manual 07 2016 Edition ...
Страница 2: ......
Страница 8: ...Preface SINAMICS G130 G150 8 List Manual LH2 07 2016 A5E03263479A ...
Страница 1940: ...4 Faults and alarms 4 2 List of faults and alarms SINAMICS G130 G150 1940 List Manual LH2 07 2016 A5E03263479A ...
Страница 1960: ...A Appendix A 3 References SINAMICS G130 G150 1960 List Manual LH2 07 2016 A5E03263479A ...
Страница 1974: ...Index SINAMICS G130 G150 1974 List Manual LH2 07 2016 A5E03263479A ...
Страница 1975: ......