2 Parameters
2.2 List of parameters
SINAMICS G130/G150
424
List Manual (LH2), 07/2016, A5E03263479A
Description:
The following applies for a synchronous reluctance motor:
Sets the ramp-up time of the current setpoint when switching over from closed-loop controlled operation to open-loop
controlled operation.
The current setpoint is calculated from p1610 and p1611.
Description:
Displays the output of the P flux controller for separately excited synchronous motors (SESM).
Description:
Sets the effective current limit within the pulse technique.
Note:
The saturation characteristic of the motor defines the available operating range for the pulse technique.
This operating range can be adjusted using the current limit.
When commissioning a catalog motor, the technique is automatically selected depending on the motor type being
used.
Otherwise, the rated motor current is used as pre-assigned value.
Description:
Sets the applied pulse patterns for estimating the continuous rotor position.
Remark:
See p1750 for the activation of the pulse-pattern technique.
Value:
1:
pm
2:
ppmm
Dependency:
Refer to: p1750
Note:
When commissioning a catalog motor, the technique is automatically selected depending on the motor type being
used.
p1601[0...n]
Current injection ramp-up time / I_inject t_ramp-up
VECTOR_G (n/M)
Can be changed:
U, T
Calculated:
CALC_MOD_REG
Access level:
3
Data type:
FloatingPoint32
Dyn. index:
DDS, p0180
Func. diagram:
6790
P-Group:
Closed-loop control
Unit group:
-
Unit selection:
-
Not for motor type:
ASM, PMSM, SESM,
REL
Scaling:
-
Expert list:
1
Min Max
Factory
setting
1 [ms]
10000 [ms]
20 [ms]
r1602
CO: P flux controller output / P flux ctrl outp
VECTOR_G (n/M)
Can be changed:
-
Calculated:
-
Access level:
4
Data type:
FloatingPoint32
Dyn. index:
-
Func. diagram:
6726, 6727
P-Group:
Closed-loop control
Unit group:
6_2
Unit selection:
p0505
Not for motor type:
ASM, PMSM, REL
Scaling:
p2002
Expert list:
1
Min Max
Factory
setting
- [Arms]
- [Arms]
- [Arms]
p1604[0...n]
Pulse technique current limit / Pulse current lim
VECTOR_G (n/M)
Can be changed:
U, T
Calculated:
CALC_MOD_CON
Access level:
3
Data type:
FloatingPoint32
Dyn. index:
DDS, p0180
Func. diagram:
-
P-Group:
Closed-loop control
Unit group:
-
Unit selection:
-
Not for motor type:
ASM, SESM, REL
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0.00 [Arms]
10000.00 [Arms]
0.00 [Arms]
p1605[0...n]
Pulse technique pattern configuration / Puls pattrn config
VECTOR_G (n/M)
Can be changed:
U, T
Calculated:
CALC_MOD_CON
Access level:
3
Data type:
Integer16
Dyn. index:
DDS, p0180
Func. diagram:
-
P-Group:
Closed-loop control
Unit group:
-
Unit selection:
-
Not for motor type:
ASM, SESM, REL
Scaling:
-
Expert list:
1
Min Max
Factory
setting
1 2
2
Содержание SINAMICS G130
Страница 1: ...s SINAMICS SINAMICS G130 G150 List Manual 07 2016 Edition ...
Страница 2: ......
Страница 8: ...Preface SINAMICS G130 G150 8 List Manual LH2 07 2016 A5E03263479A ...
Страница 1940: ...4 Faults and alarms 4 2 List of faults and alarms SINAMICS G130 G150 1940 List Manual LH2 07 2016 A5E03263479A ...
Страница 1960: ...A Appendix A 3 References SINAMICS G130 G150 1960 List Manual LH2 07 2016 A5E03263479A ...
Страница 1974: ...Index SINAMICS G130 G150 1974 List Manual LH2 07 2016 A5E03263479A ...
Страница 1975: ......