2 Parameters
2.2 List of parameters
SINAMICS G130/G150
94
List Manual (LH2), 07/2016, A5E03263479A
Description:
Configuration of the motor when commissioning the motor.
Dependency:
For standard induction motors (p0301 > 10000), bit 0 is automatically pre-assigned the connection type of the
selected data set.
For p0100 > 0 (60 Hz rated motor frequency), it is not possible to select bit 1.
Refer to: p0304, p0305
Note:
For bit 00:
When changing the bits, the rated motor voltage p0304 and the rated motor current p0305 are automatically
converted to the selected connection type (star/delta).
For instance, this can be necessary if an 1LE1 motor is selected using the Article number (MLFB) or code number
(p0300 = 100, p0301 = 1x0xx), and the motor connection type does not correspond to that of the data set.
Description:
Copying a Motor Data Set (MDS) into another.
Index:
[0] = Source motor data set
[1] = Target motor data set
[2] = Start copying procedure
Note:
Procedure:
1. In Index 0, enter which motor data set should be copied.
2. In Index 1, enter the motor data set data that is to be copied into.
3. Start copying: set index 2 from 0 to 1.
p0139[2] is automatically set to 0 when copying is completed.
When copying, p0131 is not taken into account.
Description:
Sets the number of Encoder Data Sets (EDS).
Note:
When parameterizing the drive with "no encoder" there must be at least one encoder data set (p0140 >= 1).
p0133[0...n]
Motor configuration / Motor config
VECTOR_G
Can be changed:
C2(1, 3)
Calculated:
-
Access level:
2
Data type:
Unsigned16
Dyn. index:
MDS, p0130
Func. diagram:
-
P-Group:
Motor
Unit group:
-
Unit selection:
-
Not for motor type:
PMSM, SESM, REL
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- -
0000
bin
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
Motor connection type
Delta
Star
-
p0139[0...2]
Copy Motor Data Set MDS / Copy MDS
VECTOR_G
Can be changed:
C2(15)
Calculated:
-
Access level:
2
Data type:
Unsigned8
Dyn. index:
-
Func. diagram:
8575
P-Group:
Data sets
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0 31
0
p0140
Number of Encoder Data Sets (EDS) / EDS count
VECTOR_G
Can be changed:
C1(3)
Calculated:
-
Access level:
2
Data type:
Unsigned8
Dyn. index:
-
Func. diagram:
8570
P-Group:
Data sets
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
1 16
1
Содержание SINAMICS G130
Страница 1: ...s SINAMICS SINAMICS G130 G150 List Manual 07 2016 Edition ...
Страница 2: ......
Страница 8: ...Preface SINAMICS G130 G150 8 List Manual LH2 07 2016 A5E03263479A ...
Страница 1940: ...4 Faults and alarms 4 2 List of faults and alarms SINAMICS G130 G150 1940 List Manual LH2 07 2016 A5E03263479A ...
Страница 1960: ...A Appendix A 3 References SINAMICS G130 G150 1960 List Manual LH2 07 2016 A5E03263479A ...
Страница 1974: ...Index SINAMICS G130 G150 1974 List Manual LH2 07 2016 A5E03263479A ...
Страница 1975: ......