SINAMICS G130/G150
List Manual (LH2), 07/2016, A5E03263479A
585
2 Parameters
2.2 List of parameters
Description:
Display and BICO output for the result of the AND logic operation.
Dependency:
Refer to: p2810
Description:
Sets the signal sources for the inputs of the OR logic operation.
Dependency:
Refer to: r2817
Note:
[0]: OR logic operation, input 1 --> the result is displayed in r2817.0.
[1]: OR logic operation, input 2 --> the result is displayed in r2817.0.
Description:
Display and BICO output for the result of the OR logic operation.
Dependency:
Refer to: p2816
Description:
Sets the signal sources for the inputs of the NOT logic operations.
Index:
[0] = NOT logic operation 0 input
[1] = NOT logic operation 1 input
[2] = NOT logic operation 2 input
[3] = NOT logic operation 3 input
Dependency:
Refer to: r2823
Note:
[0]: NOT logic operation 0 --> result is displayed in r2823.0.
[1]: NOT logic operation 1 --> result is displayed in r2823.1.
r2811.0
CO/BO: AND logic operation result / AND result
VECTOR_G
Can be changed:
-
Calculated:
-
Access level:
2
Data type:
Unsigned32
Dyn. index:
-
Func. diagram:
2634
P-Group:
Functions
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- -
-
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
AND condition fulfilled
Yes
No
-
p2816[0...1]
BI: OR logic operation inputs / OR inputs
VECTOR_G
Can be changed:
T
Calculated:
-
Access level:
2
Data type:
Unsigned32 / Binary
Dyn. index:
-
Func. diagram:
2634
P-Group:
Functions
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- -
0
r2817.0
CO/BO: OR logic operation result / OR result
VECTOR_G
Can be changed:
-
Calculated:
-
Access level:
2
Data type:
Unsigned32
Dyn. index:
-
Func. diagram:
2634
P-Group:
Functions
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- -
-
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
OR condition fulfilled
Yes
No
-
p2822[0...3]
BI: NOT logic operation input / NOT input
VECTOR_G
Can be changed:
T
Calculated:
-
Access level:
2
Data type:
Unsigned32 / Binary
Dyn. index:
-
Func. diagram:
2634
P-Group:
Functions
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- -
0
Содержание SINAMICS G130
Страница 1: ...s SINAMICS SINAMICS G130 G150 List Manual 07 2016 Edition ...
Страница 2: ......
Страница 8: ...Preface SINAMICS G130 G150 8 List Manual LH2 07 2016 A5E03263479A ...
Страница 1940: ...4 Faults and alarms 4 2 List of faults and alarms SINAMICS G130 G150 1940 List Manual LH2 07 2016 A5E03263479A ...
Страница 1960: ...A Appendix A 3 References SINAMICS G130 G150 1960 List Manual LH2 07 2016 A5E03263479A ...
Страница 1974: ...Index SINAMICS G130 G150 1974 List Manual LH2 07 2016 A5E03263479A ...
Страница 1975: ......