SINAMICS G130/G150
List Manual (LH2), 07/2016, A5E03263479A
1009
2 Parameters
2.2 List of parameters
Description:
Display and BICO output for the Safety Integrated status on the Motor Module/Hydraulic Module.
Dependency:
Refer to: r9772
Notice:
If communication between both monitoring channels is interrupted (e.g. by switching off the power unit), this display
parameter is no longer updated. The last transferred status of the Motor Module/Hydraulic Module is displayed.
Note:
For bit 00:
When STO is selected, the cause is displayed in bits 16 ... 21.
For bit 05:
When SS1 is selected, the cause is displayed in bits 22 and 23.
For bit 18:
When the bit is set, STO is selected via PROFIsafe or Terminal Module 54F (TM54F).
SMM: Safe Motion Monitoring
For bit 22, 23:
These bits show via which path the SS1 was triggered, i.e. what has started the SS1 delay time.
If the SS1 delay time is not started (e.g. because an STO is triggered at the same time), neither of the two bits is set.
For bit 24:
Only for a parallel connection and active motion monitoring functions.
r9872.0...24
CO/BO: SI status list (Motor Module) / SI status MM
VECTOR_G
Can be changed:
-
Calculated:
-
Access level:
2
Data type:
Unsigned32
Dyn. index:
-
Func. diagram:
2804
P-Group:
Safety Integrated
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- -
-
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
STO selected on MM
Yes
No
2810
01
STO on MM act
Yes
No
2810
02
SS1 delay time active on MM
Yes
No
2810
03
Safe Brake Adapter feedback signal
Yes
No
2814
04
SBC requested
Yes
No
2814
05
SS1 selected on MM (Basic Functions)
Yes
No
-
06
SS1 active on MM (Basic Functions)
Yes
No
-
07
STO terminal state on MM (Basic
Functions)
High
Low
-
09
STOP A cannot be acknowledged active
Yes
No
2802
10
STOP A active
Yes
No
2802
15
STOP F active
Yes
No
2802
16
STO cause: Safety comm. mode
Yes
No
-
17
STO cause selection via terminal (Basic
Functions)
Yes
No
-
18
STO cause: selection via SMM
Yes
No
-
20
STO cause selection PROFIsafe/TM54F
(Basic Functions)
Yes
No
-
21
STO cause selection on other monitoring
channel
Yes
No
-
22
SS1 cause selection terminal (Basic
Functions)
Yes
No
-
23
SS1 cause selection PROFIsafe/TM54F
(Basic Functions)
Yes
No
-
24
Slave MM ready for communication
Yes
No
-
Содержание SINAMICS G130
Страница 1: ...s SINAMICS SINAMICS G130 G150 List Manual 07 2016 Edition ...
Страница 2: ......
Страница 8: ...Preface SINAMICS G130 G150 8 List Manual LH2 07 2016 A5E03263479A ...
Страница 1940: ...4 Faults and alarms 4 2 List of faults and alarms SINAMICS G130 G150 1940 List Manual LH2 07 2016 A5E03263479A ...
Страница 1960: ...A Appendix A 3 References SINAMICS G130 G150 1960 List Manual LH2 07 2016 A5E03263479A ...
Страница 1974: ...Index SINAMICS G130 G150 1974 List Manual LH2 07 2016 A5E03263479A ...
Страница 1975: ......