SINAMICS G130/G150
List Manual (LH2), 07/2016, A5E03263479A
481
2 Parameters
2.2 List of parameters
Description:
Displays the identified effective valve lockout time.
Index:
[0] = Phase U
[1] = Phase V
[2] = Phase W
Description:
Displays identified rotor resistance (on separately excited synchronous motors: damping resistance).
Index:
[0] = Phase U
[1] = Phase V
[2] = Phase W
Description:
Displays the identified cable resistance.
Index:
[0] = Phase U
[1] = Phase V
[2] = Phase W
Description:
Displays the identified (differential) q-inductance.
Dependency:
Refer to: r1935, p1959, p1960
Note:
The Lq characteristic consists of the value pairs from p1934 and p1935 with the same index.
This value corresponds to the value of the total leakage inductance (r0377).
r1926[0...2]
Identified effective valve lockout time / t_lock_valve id
VECTOR_G
Can be changed:
-
Calculated:
-
Access level:
4
Data type:
FloatingPoint32
Dyn. index:
-
Func. diagram:
-
P-Group:
Motor identification
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- [µs]
- [µs]
- [µs]
r1927[0...2]
Identified rotor resistance / R_rotor ident
VECTOR_G
Can be changed:
-
Calculated:
-
Access level:
4
Data type:
FloatingPoint32
Dyn. index:
-
Func. diagram:
-
P-Group:
Motor identification
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- [ohm]
- [ohm]
- [ohm]
r1929[0...2]
Identified cable resistance / R_cable ident
VECTOR_G
Can be changed:
-
Calculated:
-
Access level:
4
Data type:
FloatingPoint32
Dyn. index:
-
Func. diagram:
-
P-Group:
Motor identification
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- [ohm]
- [ohm]
- [ohm]
r1934[0...9]
q inductance identified / Lq ident
VECTOR_G (n/M)
Can be changed:
-
Calculated:
-
Access level:
4
Data type:
FloatingPoint32
Dyn. index:
-
Func. diagram:
-
P-Group:
Motor identification
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- [mH]
- [mH]
- [mH]
Содержание SINAMICS G130
Страница 1: ...s SINAMICS SINAMICS G130 G150 List Manual 07 2016 Edition ...
Страница 2: ......
Страница 8: ...Preface SINAMICS G130 G150 8 List Manual LH2 07 2016 A5E03263479A ...
Страница 1940: ...4 Faults and alarms 4 2 List of faults and alarms SINAMICS G130 G150 1940 List Manual LH2 07 2016 A5E03263479A ...
Страница 1960: ...A Appendix A 3 References SINAMICS G130 G150 1960 List Manual LH2 07 2016 A5E03263479A ...
Страница 1974: ...Index SINAMICS G130 G150 1974 List Manual LH2 07 2016 A5E03263479A ...
Страница 1975: ......