SINAMICS G130/G150
List Manual (LH2), 07/2016, A5E03263479A
247
2 Parameters
2.2 List of parameters
Description:
Sets the factor to evaluate the stator resistance.
Dependency:
Refer to: p0350, r0370
Description:
Sets the factor to evaluate the stator leakage induction.
Dependency:
Refer to: p0356, r0377
Description:
Factor to evaluate the magnetizing inductance in the direction of the rotor axis (d axis).
Dependency:
Refer to: p0360, r0382
Description:
Factor to evaluate the magnetizing inductance quadrature to the rotor axis (q axis).
Dependency:
Refer to: p0361, r0383
Description:
Factor to evaluate the damping inductance in the direction of the rotor axis (d axis).
Dependency:
Refer to: p0358, r0380
p0652[0...n]
Motor stator resistance scaling / Mot R_stator scal
VECTOR_G
Can be changed:
C2(3), U, T
Calculated:
CALC_MOD_EQU
Access level:
4
Data type:
FloatingPoint32
Dyn. index:
MDS, p0130
Func. diagram:
-
P-Group:
Motor
Unit group:
-
Unit selection:
-
Not for motor type:
ASM, PMSM, REL
Scaling:
-
Expert list:
1
Min Max
Factory
setting
10.0 [%]
300.0 [%]
100.0 [%]
p0653[0...n]
Motor stator leakage inductance scaling / Mot L_S_leak scal
VECTOR_G
Can be changed:
C2(3), U, T
Calculated:
CALC_MOD_EQU
Access level:
4
Data type:
FloatingPoint32
Dyn. index:
MDS, p0130
Func. diagram:
-
P-Group:
Motor
Unit group:
-
Unit selection:
-
Not for motor type:
ASM, PMSM, REL
Scaling:
-
Expert list:
1
Min Max
Factory
setting
10.0 [%]
300.0 [%]
100.0 [%]
p0655[0...n]
Motor magnetizing inductance d axis saturated scaling / Mot L_m d sat scal
VECTOR_G
Can be changed:
C2(3), U, T
Calculated:
CALC_MOD_EQU
Access level:
4
Data type:
FloatingPoint32
Dyn. index:
MDS, p0130
Func. diagram:
6727
P-Group:
Motor
Unit group:
-
Unit selection:
-
Not for motor type:
ASM, PMSM, REL
Scaling:
-
Expert list:
1
Min Max
Factory
setting
10.0 [%]
300.0 [%]
100.0 [%]
p0656[0...n]
Motor magnetizing inductance q axis saturated scaling / Mot L_m q sat scal
VECTOR_G
Can be changed:
C2(3), U, T
Calculated:
CALC_MOD_EQU
Access level:
4
Data type:
FloatingPoint32
Dyn. index:
MDS, p0130
Func. diagram:
6727
P-Group:
Motor
Unit group:
-
Unit selection:
-
Not for motor type:
ASM, PMSM, REL
Scaling:
-
Expert list:
1
Min Max
Factory
setting
10.0 [%]
300.0 [%]
100.0 [%]
p0657[0...n]
Motor damping inductance d axis scaling / Mot L_damp d scal
VECTOR_G
Can be changed:
C2(3), U, T
Calculated:
CALC_MOD_EQU
Access level:
4
Data type:
FloatingPoint32
Dyn. index:
MDS, p0130
Func. diagram:
6727
P-Group:
Motor
Unit group:
-
Unit selection:
-
Not for motor type:
ASM, PMSM, REL
Scaling:
-
Expert list:
1
Min Max
Factory
setting
10.0 [%]
300.0 [%]
100.0 [%]
Содержание SINAMICS G130
Страница 1: ...s SINAMICS SINAMICS G130 G150 List Manual 07 2016 Edition ...
Страница 2: ......
Страница 8: ...Preface SINAMICS G130 G150 8 List Manual LH2 07 2016 A5E03263479A ...
Страница 1940: ...4 Faults and alarms 4 2 List of faults and alarms SINAMICS G130 G150 1940 List Manual LH2 07 2016 A5E03263479A ...
Страница 1960: ...A Appendix A 3 References SINAMICS G130 G150 1960 List Manual LH2 07 2016 A5E03263479A ...
Страница 1974: ...Index SINAMICS G130 G150 1974 List Manual LH2 07 2016 A5E03263479A ...
Страница 1975: ......