SINAMICS G130/G150
List Manual (LH2), 07/2016, A5E03263479A
763
2 Parameters
2.2 List of parameters
Description:
Displays depletion layer temperature 5 in the power unit for a parallel circuit configuration.
The maximum value of all power units is displayed in r0037[17].
Description:
Displays depletion layer temperature 6 in the power unit for a parallel circuit configuration.
The maximum value of all power units is displayed in r0037[18].
Description:
Displays the maximum output current of the power unit.
The minimum value of all power units multiplied by the number of Motor Modules is displayed in r0067.
Description:
Displays actual absolute current.
The summed value of all power units is displayed in r0068.
Description:
Displays the measured actual value of phase U as peak value.
The summed value of all power units is displayed in r0069[0].
r7218[0...n]
Par_circuit power unit temperatures depletion layer 5 / PU temp DepLayer 5
VECTOR_G (Parallel),
B_INF (Parallel)
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
FloatingPoint32
Dyn. index:
PDS, p0120
Func. diagram:
-
P-Group:
Displays, signals
Unit group:
21_1
Unit selection:
p0505
Not for motor type:
-
Scaling:
p2006
Expert list:
1
Min Max
Factory
setting
- [°C]
- [°C]
- [°C]
r7219[0...n]
Par_circuit power unit temperatures depletion layer 6 / PU temp DepLayer 6
VECTOR_G (Parallel),
B_INF (Parallel)
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
FloatingPoint32
Dyn. index:
PDS, p0120
Func. diagram:
-
P-Group:
Displays, signals
Unit group:
21_1
Unit selection:
p0505
Not for motor type:
-
Scaling:
p2006
Expert list:
1
Min Max
Factory
setting
- [°C]
- [°C]
- [°C]
r7220[0...n]
CO: Par_circuit drive output current maximum / Drv I_outp max
VECTOR_G (Parallel)
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
FloatingPoint32
Dyn. index:
PDS, p0120
Func. diagram:
-
P-Group:
Displays, signals
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
p2002
Expert list:
1
Min Max
Factory
setting
- [Arms]
- [Arms]
- [Arms]
r7222[0...n]
CO: Par_circuit absolute current actual value / I_act abs val
VECTOR_G (Parallel)
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
FloatingPoint32
Dyn. index:
PDS, p0120
Func. diagram:
-
P-Group:
Displays, signals
Unit group:
6_2
Unit selection:
p0505
Not for motor type:
-
Scaling:
p2002
Expert list:
1
Min Max
Factory
setting
- [Arms]
- [Arms]
- [Arms]
r7223[0...n]
CO: Par_circuit phase current actual value phase U / I_phase U act val
VECTOR_G (Parallel)
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
FloatingPoint32
Dyn. index:
PDS, p0120
Func. diagram:
-
P-Group:
Displays, signals
Unit group:
6_5
Unit selection:
p0505
Not for motor type:
-
Scaling:
p2002
Expert list:
1
Min Max
Factory
setting
- [A]
- [A]
- [A]
Содержание SINAMICS G130
Страница 1: ...s SINAMICS SINAMICS G130 G150 List Manual 07 2016 Edition ...
Страница 2: ......
Страница 8: ...Preface SINAMICS G130 G150 8 List Manual LH2 07 2016 A5E03263479A ...
Страница 1940: ...4 Faults and alarms 4 2 List of faults and alarms SINAMICS G130 G150 1940 List Manual LH2 07 2016 A5E03263479A ...
Страница 1960: ...A Appendix A 3 References SINAMICS G130 G150 1960 List Manual LH2 07 2016 A5E03263479A ...
Страница 1974: ...Index SINAMICS G130 G150 1974 List Manual LH2 07 2016 A5E03263479A ...
Страница 1975: ......