SINAMICS G130/G150
List Manual (LH2), 07/2016, A5E03263479A
893
2 Parameters
2.2 List of parameters
Index 2: Minimum time of all acyclic requests referred to the parameter Id (index 0).
Index 3: Maximum time of all acyclic requests referred to the parameter Id (index 0).
Index 4: Average of all acyclic requests referred to the parameter Id (index 0).
The time unit is 10 µs.
Dependency:
The number of statistic entries is displayed in p9220.
In p9221, the component Id can be set whose statistic is to be displayed.
Refer to: r9220, p9221
Note:
As a statistic entry comprises 5 data, when calling the entries via the terminal, a size that represents a multiple of 5
must be specified.
Example:
The 2nd entry should be called:
rdp 1 9222 5 5
or
rdpa 1 9222 5 5
Description:
Sets the monitoring clock cycle for safe motion monitoring.
Dependency:
Refer to: p9500, p9511
Refer to: F01652
Notice:
This parameter is overwritten by the copy function of the safety functions integrated in the drive.
Note:
The monitoring clock cycle must be a multiple of the actual value sensing clock cycle in p9311 or of the DP clock
cycle.
A change only becomes effective after a POWER ON.
Description:
Sets the enable signals for the safe motion monitoring.
Dependency:
Refer to: p9501
Refer to: F01682, F01683
Notice:
This parameter is overwritten by the copy function of the safety functions integrated in the drive.
p9300
SI Motion monitoring clock cycle (Motor Module) / SI Mtn clock MM
VECTOR_G
Can be changed:
C2(95)
Calculated:
-
Access level:
3
Data type:
FloatingPoint32
Dyn. index:
-
Func. diagram:
-
P-Group:
Safety Integrated
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
500.00 [µs]
25000.00 [µs]
12000.00 [µs]
p9301
SI Motion enable safety functions (Motor Module) / SI Mtn enable MM
VECTOR_G
Can be changed:
C2(95)
Calculated:
-
Access level:
3
Data type:
Unsigned32
Dyn. index:
-
Func. diagram:
-
P-Group:
Safety Integrated
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
-
-
0000 0000 0000 0000 0000
0000 0000 0000 bin
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
Enable SOS/SLS
Enable
Inhibit
-
01
Enable SLP
Enable
Inhibit
-
02
Enable absolute position
Enable
Inhibit
-
03
Enable actual value synchronization
Enable
Inhibit
-
16
Enable SSM hysteresis and filtering
Enable
Inhibit
2823
17
Enable SDI
Enable
Inhibit
2824
18
Enable SS2E
Enable
Inhibit
-
24
Enable transfer SLS limit value via
PROFIsafe
Enable
Inhibit
-
25
Enable transfer safe position via PROFIsafe Enable
Inhibit
-
26
Enable safe gearbox switchover
Enable
Inhibit
-
27
Enable referencing via SCC
Enable
Inhibit
-
Содержание SINAMICS G130
Страница 1: ...s SINAMICS SINAMICS G130 G150 List Manual 07 2016 Edition ...
Страница 2: ......
Страница 8: ...Preface SINAMICS G130 G150 8 List Manual LH2 07 2016 A5E03263479A ...
Страница 1940: ...4 Faults and alarms 4 2 List of faults and alarms SINAMICS G130 G150 1940 List Manual LH2 07 2016 A5E03263479A ...
Страница 1960: ...A Appendix A 3 References SINAMICS G130 G150 1960 List Manual LH2 07 2016 A5E03263479A ...
Страница 1974: ...Index SINAMICS G130 G150 1974 List Manual LH2 07 2016 A5E03263479A ...
Страница 1975: ......