2 Parameters
2.2 List of parameters
SINAMICS G130/G150
432
List Manual (LH2), 07/2016, A5E03263479A
Description:
Displays the magnetizing current of the current model in the q-axis.
Description:
Displays the stator current in the q axis after the current actual value tracking.
Description:
Sets the signal source for the excitation current actual value
Description:
Displays the excitation current actual value that is read in.
Index:
[0] = Excitation current of the excitation equipment
[1] = Excitation current for direct excitation
Dependency:
Refer to: p0390
Note:
The following applies for index 0:
For direct excitation, the value is referred to p0390. For brushless excitation, the value is referred to p0690.
The following applies for index 1:
The value is referred to p0390.
Description:
Sets the minimum excitation current.
This means that negative excitation currents can be avoided.
r1638
Current model magnetizing current q axis / I_mod I_mag q-ax
VECTOR_G (n/M)
Can be changed:
-
Calculated:
-
Access level:
4
Data type:
FloatingPoint32
Dyn. index:
-
Func. diagram:
6727
P-Group:
Closed-loop control
Unit group:
6_2
Unit selection:
p0505
Not for motor type:
ASM, PMSM, REL
Scaling:
p2002
Expert list:
1
Min Max
Factory
setting
- [Arms]
- [Arms]
- [Arms]
r1639
CO: Current model Isq after actual value tracking / I_mod Isq track
VECTOR_G (n/M)
Can be changed:
-
Calculated:
-
Access level:
4
Data type:
FloatingPoint32
Dyn. index:
-
Func. diagram:
6727
P-Group:
Closed-loop control
Unit group:
6_2
Unit selection:
p0505
Not for motor type:
ASM, PMSM, REL
Scaling:
p2002
Expert list:
1
Min Max
Factory
setting
- [Arms]
- [Arms]
- [Arms]
p1640[0...n]
CI: Excitation current actual value signal source / I_exc_ActVal S_src
VECTOR_G (n/M)
Can be changed:
T
Calculated:
-
Access level:
3
Data type:
Unsigned32 / FloatingPoint32
Dyn. index:
CDS, p0170
Func. diagram:
6727
P-Group:
Closed-loop control
Unit group:
-
Unit selection:
-
Not for motor type:
ASM, PMSM, REL
Scaling:
PERCENT
Expert list:
1
Min Max
Factory
setting
- -
0
r1641[0...1]
Excitation current actual value / I_exc_act val
VECTOR_G (n/M)
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
FloatingPoint32
Dyn. index:
-
Func. diagram:
6727, 8020
P-Group:
Closed-loop control
Unit group:
-
Unit selection:
-
Not for motor type:
ASM, PMSM, REL
Scaling:
PERCENT
Expert list:
1
Min Max
Factory
setting
- [%]
- [%]
- [%]
p1642[0...n]
Minimum excitation current / Min I_exc
VECTOR_G (n/M)
Can be changed:
U, T
Calculated:
-
Access level:
4
Data type:
FloatingPoint32
Dyn. index:
DDS, p0180
Func. diagram:
6727
P-Group:
Closed-loop control
Unit group:
-
Unit selection:
-
Not for motor type:
ASM, PMSM, REL
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0.1 [%]
50.0 [%]
5.0 [%]
Содержание SINAMICS G130
Страница 1: ...s SINAMICS SINAMICS G130 G150 List Manual 07 2016 Edition ...
Страница 2: ......
Страница 8: ...Preface SINAMICS G130 G150 8 List Manual LH2 07 2016 A5E03263479A ...
Страница 1940: ...4 Faults and alarms 4 2 List of faults and alarms SINAMICS G130 G150 1940 List Manual LH2 07 2016 A5E03263479A ...
Страница 1960: ...A Appendix A 3 References SINAMICS G130 G150 1960 List Manual LH2 07 2016 A5E03263479A ...
Страница 1974: ...Index SINAMICS G130 G150 1974 List Manual LH2 07 2016 A5E03263479A ...
Страница 1975: ......