2 Parameters
2.2 List of parameters
Description:
Sets the resolution of the absolute position for a linear absolute encoder.
Notice:
This parameter is automatically preassigned for encoders from the encoder list and for identify encoder (p0400).
When selecting a catalog encoder, this parameter cannot be changed (write protection). Information in p0400 should
be carefully observed when removing write protection.
Note:
The serial protocol of an absolute encoder provides the position with a certain resolution (e.g. 100 nm). This value
must be entered here.
Description:
Sets the number of measuring steps per revolution for a rotary absolute encoder.
The resolution refers to the absolute position.
Notice:
This parameter is automatically preassigned for encoders from the encoder list and for identify encoder (p0400).
When selecting a catalog encoder, this parameter cannot be changed (write protection). Information in p0400 should
be carefully observed when removing write protection.
Description:
Sets the distance between two zero marks for a linear encoder.
This information is used for zero mark monitoring.
Notice:
This parameter is automatically preassigned for encoders from the encoder list and for identify encoder (p0400).
When selecting a catalog encoder, this parameter cannot be changed (write protection). Information in p0400 should
be carefully observed when removing write protection.
Note:
For distance-coded zero marks this parameter signifies the basic distance.
Description:
Sets the distance in pulses between two zero marks for a rotary encoder.
This information is used for zero mark monitoring.
Notice:
This parameter is automatically preassigned for encoders from the encoder list and for identify encoder (p0400).
When selecting a catalog encoder, this parameter cannot be changed (write protection). Information in p0400 should
be carefully observed when removing write protection.
p0422[0...n]
Absolute encoder linear measuring step resolution / Enc abs meas step
VECTOR_G, ENC
Can be changed:
C2(4)
Calculated:
-
Access level:
3
Data type:
Unsigned32
Dyn. index:
EDS, p0140
Func. diagram:
4704
P-Group:
Encoder
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0 [nm]
4294967295 [nm]
100 [nm]
p0423[0...n]
Absolute encoder rotary singleturn resolution / Enc abs singleturn
VECTOR_G, ENC
Can be changed:
C2(4)
Calculated:
-
Access level:
3
Data type:
Unsigned32
Dyn. index:
EDS, p0140
Func. diagram:
4704
P-Group:
Encoder
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0 1073741823
8192
p0424[0...n]
Encoder linear zero mark distance / Enc lin ZM_dist
VECTOR_G, ENC
Can be changed:
C2(4)
Calculated:
-
Access level:
3
Data type:
Unsigned16
Dyn. index:
EDS, p0140
Func. diagram:
-
P-Group:
Encoder
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0 [mm]
65535 [mm]
20 [mm]
p0425[0...n]
Encoder rotary zero mark distance / Enc rot dist ZM
VECTOR_G, ENC
Can be changed:
C2(4)
Calculated:
-
Access level:
3
Data type:
Unsigned32
Dyn. index:
EDS, p0140
Func. diagram:
4704, 8570
P-Group:
Encoder
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0 16777215
2048
Содержание SINAMICS G130
Страница 1: ...s SINAMICS SINAMICS G130 G150 List Manual 07 2016 Edition ...
Страница 2: ......
Страница 8: ...Preface SINAMICS G130 G150 8 List Manual LH2 07 2016 A5E03263479A ...
Страница 1940: ...4 Faults and alarms 4 2 List of faults and alarms SINAMICS G130 G150 1940 List Manual LH2 07 2016 A5E03263479A ...
Страница 1960: ...A Appendix A 3 References SINAMICS G130 G150 1960 List Manual LH2 07 2016 A5E03263479A ...
Страница 1974: ...Index SINAMICS G130 G150 1974 List Manual LH2 07 2016 A5E03263479A ...
Страница 1975: ......