2 Parameters
2.2 List of parameters
SINAMICS G130/G150
82
List Manual (LH2), 07/2016, A5E03263479A
Description:
Displays the activated function module for the particular drive object.
Dependency:
Refer to: p0171, r0171, p0172, r0172, p0173, r0173
Note:
A "function module" is a functional expansion of a drive object that can be activated when commissioning.
The following bits are only automatically set, if the power units are detected with the appropriate properties.
Bit 16: Parallel connection of the same power units (only automatically set for G130/G150).
Bit 20: Software gating unit (only automatically set when power units are connected in parallel).
Bit 24: Type PM330 power units are presently not supported.
Bit 26: Type PM250 power units with F3E energy recovery are only supported for S120 CRANES.
Bit 28: Power units with liquid cooling.
Description:
Displays the activated function module for the particular drive object.
Dependency:
Refer to: p0171, r0171, p0172, r0172, p0173, r0173
Note:
A "function module" is a functional expansion of a drive object that can be activated when commissioning.
r0108
Drive objects function module / DO fct_mod
VECTOR_G
Can be changed:
-
Calculated:
-
Access level:
2
Data type:
Unsigned32
Dyn. index:
-
Func. diagram:
-
P-Group:
Closed-loop control
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- -
-
Bit field:
Bit
Signal name
1 signal
0 signal
FP
02
Speed/torque control / n/M
Activated
Not activated
-
05
Recorder / Rec
Activated
Not activated
-
08
Extended setpoint channel / Ext setp
Activated
Not activated
-
10
Moment of inertia estimator / J_estimator
Activated
Not activated
-
13
Safety rotary axis / Safety rot
Activated
Not activated
-
14
Extended brake control / Ext brake
Activated
Not activated
-
15
Parallel connection / Parallel
Activated
Not activated
-
16
Technology controller / Tech_ctrl
Activated
Not activated
-
17
Extended messages/monitoring / Ext msg
Activated
Not activated
-
18
Free function blocks / FBLOCKS
Activated
Not activated
-
20
Software gating unit / SW_gating unit
Activated
Not activated
-
24
PM330 / PM330
Activated
Not activated
-
28
Cooling unit / Cool_unit
Activated
Not activated
-
29
CAN / CAN
Activated
Not activated
-
31
PROFINET CBE20 / PN CBE20
Activated
Not activated
-
r0108
Drive objects function module / DO fct_mod
B_INF
Can be changed:
-
Calculated:
-
Access level:
2
Data type:
Unsigned32
Dyn. index:
-
Func. diagram:
-
P-Group:
Closed-loop control
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- -
-
Bit field:
Bit
Signal name
1 signal
0 signal
FP
05
Recorder / Rec
Activated
Not activated
-
15
Parallel connection / Parallel
Activated
Not activated
-
18
Free function blocks / FBLOCKS
Activated
Not activated
-
26
Braking Module external / Brk Mod ext
Activated
Not activated
-
28
Cooling unit / Cool_unit
Activated
Not activated
-
31
PROFINET CBE20 / PN CBE20
Activated
Not activated
-
Содержание SINAMICS G130
Страница 1: ...s SINAMICS SINAMICS G130 G150 List Manual 07 2016 Edition ...
Страница 2: ......
Страница 8: ...Preface SINAMICS G130 G150 8 List Manual LH2 07 2016 A5E03263479A ...
Страница 1940: ...4 Faults and alarms 4 2 List of faults and alarms SINAMICS G130 G150 1940 List Manual LH2 07 2016 A5E03263479A ...
Страница 1960: ...A Appendix A 3 References SINAMICS G130 G150 1960 List Manual LH2 07 2016 A5E03263479A ...
Страница 1974: ...Index SINAMICS G130 G150 1974 List Manual LH2 07 2016 A5E03263479A ...
Страница 1975: ......