2 Parameters
2.2 List of parameters
Note:
The reference value to identify the stator resistance should be manually entered after the first identification (p0629 =
r0623). The identification must be realized when the motor is in a cold state, as the value refers to the ambient
temperature p0625. The feeder cable resistance should be entered into p0352 before the measurement.
The result must be saved after the first measurement so that the reference is available after the CU has powered up.
When changing p0350 or p0352, the reference value p0629 should be re-determined.
Description:
Displays the ambient temperature of the motor temperature model (models 2 and 3).
Description:
Displays the stator iron temperature of the motor temperature model (models 2 and 3).
Note:
For motor temperature model 1 (p0612.0 = 1), this parameter is not valid:
Description:
Displays the stator winding temperature of the motor temperature model.
Dependency:
Refer to: F07011, A07012, A07910
Note:
For motor temperature model 1 (p0612.0 = 1), this parameter is not valid:
Description:
Displays the rotor temperature of the motor temperature model (models 2 and 3).
Note:
For motor temperature model 1 (p0612.0 = 1), this parameter is not valid:
r0630[0...n]
Mot_temp_mod ambient temperature / Mod T_ambient
VECTOR_G
Can be changed:
-
Calculated:
-
Access level:
4
Data type:
FloatingPoint32
Dyn. index:
MDS, p0130
Func. diagram:
8018
P-Group:
Motor
Unit group:
21_1
Unit selection:
p0505
Not for motor type:
SESM, REL
Scaling:
p2006
Expert list:
1
Min Max
Factory
setting
- [°C]
- [°C]
- [°C]
r0631[0...n]
Mot_temp_mod stator iron temperature / Mod T_stator
VECTOR_G
Can be changed:
-
Calculated:
-
Access level:
4
Data type:
FloatingPoint32
Dyn. index:
MDS, p0130
Func. diagram:
8018, 8019
P-Group:
Motor
Unit group:
21_1
Unit selection:
p0505
Not for motor type:
SESM, REL
Scaling:
p2006
Expert list:
1
Min Max
Factory
setting
- [°C]
- [°C]
- [°C]
r0632[0...n]
Mot_temp_mod stator winding temperature / Mod T_winding
VECTOR_G
Can be changed:
-
Calculated:
-
Access level:
2
Data type:
FloatingPoint32
Dyn. index:
MDS, p0130
Func. diagram:
8017, 8018,
8019
P-Group:
Motor
Unit group:
21_1
Unit selection:
p0505
Not for motor type:
SESM, REL
Scaling:
p2006
Expert list:
1
Min Max
Factory
setting
- [°C]
- [°C]
- [°C]
r0633[0...n]
Mot_temp_mod rotor temperature / Mod rotor temp
VECTOR_G
Can be changed:
-
Calculated:
-
Access level:
4
Data type:
FloatingPoint32
Dyn. index:
MDS, p0130
Func. diagram:
8018, 8019
P-Group:
Motor
Unit group:
21_1
Unit selection:
p0505
Not for motor type:
SESM, REL
Scaling:
p2006
Expert list:
1
Min Max
Factory
setting
- [°C]
- [°C]
- [°C]
Содержание SINAMICS G130
Страница 1: ...s SINAMICS SINAMICS G130 G150 List Manual 07 2016 Edition ...
Страница 2: ......
Страница 8: ...Preface SINAMICS G130 G150 8 List Manual LH2 07 2016 A5E03263479A ...
Страница 1940: ...4 Faults and alarms 4 2 List of faults and alarms SINAMICS G130 G150 1940 List Manual LH2 07 2016 A5E03263479A ...
Страница 1960: ...A Appendix A 3 References SINAMICS G130 G150 1960 List Manual LH2 07 2016 A5E03263479A ...
Страница 1974: ...Index SINAMICS G130 G150 1974 List Manual LH2 07 2016 A5E03263479A ...
Страница 1975: ......