2 Parameters
2.2 List of parameters
Description:
Displays the damping resistance of the separately excited synchronous motor quadrature to the rotor direction (q
axis).
Description:
Displays the nominal rotor / secondary section resistance of the motor at the rated temperature.
The rated temperature is the sum of p0625 and p0628.
Dependency:
Refer to: p0628
Note:
The parameter is not used for synchronous motors (p0300 = 2xx).
Description:
Displays the total stray inductance of the motor.
Induction motor, separately excited synchronous motor:
Displays the stator leakage inductance of the motor, including the series inductance (p0353) and the motor reactor
(p0233).
Synchronous motor:
Displays the stator quadrature inductance, including the series inductance (p0353) and the motor reactor (p0233).
Description:
Displays the stator longitudinal inductance of the synchronous motor including the series inductance (p0353) and the
motor reactor (p0233).
Note:
The parameter is not used for separately excited synchronous motors (p0300 = 5).
r0375[0...n]
Motor damping resistance q axis / Mot R_damp q
VECTOR_G
Can be changed:
-
Calculated:
-
Access level:
4
Data type:
FloatingPoint32
Dyn. index:
MDS, p0130
Func. diagram:
-
P-Group:
Motor
Unit group:
16_1
Unit selection:
p0349
Not for motor type:
ASM, PMSM, REL,
RESM
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- [ohm]
- [ohm]
- [ohm]
r0376[0...n]
Rated motor rotor resistance / Mot rated R_rotor
VECTOR_G
Can be changed:
-
Calculated:
-
Access level:
4
Data type:
FloatingPoint32
Dyn. index:
MDS, p0130
Func. diagram:
-
P-Group:
Motor
Unit group:
16_1
Unit selection:
p0349
Not for motor type:
PMSM, SESM, REL,
RESM
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- [ohm]
- [ohm]
- [ohm]
r0377[0...n]
Motor leakage inductance total / Mot L_leak total
VECTOR_G
Can be changed:
-
Calculated:
-
Access level:
4
Data type:
FloatingPoint32
Dyn. index:
MDS, p0130
Func. diagram:
6640
P-Group:
Motor
Unit group:
15_1
Unit selection:
p0349
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- [mH]
- [mH]
- [mH]
r0378[0...n]
Motor stator inductance d axis / Mot L_stator d
VECTOR_G
Can be changed:
-
Calculated:
-
Access level:
4
Data type:
FloatingPoint32
Dyn. index:
MDS, p0130
Func. diagram:
-
P-Group:
Motor
Unit group:
15_1
Unit selection:
p0349
Not for motor type:
ASM, SESM, REL
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- [mH]
- [mH]
- [mH]
Содержание SINAMICS G130
Страница 1: ...s SINAMICS SINAMICS G130 G150 List Manual 07 2016 Edition ...
Страница 2: ......
Страница 8: ...Preface SINAMICS G130 G150 8 List Manual LH2 07 2016 A5E03263479A ...
Страница 1940: ...4 Faults and alarms 4 2 List of faults and alarms SINAMICS G130 G150 1940 List Manual LH2 07 2016 A5E03263479A ...
Страница 1960: ...A Appendix A 3 References SINAMICS G130 G150 1960 List Manual LH2 07 2016 A5E03263479A ...
Страница 1974: ...Index SINAMICS G130 G150 1974 List Manual LH2 07 2016 A5E03263479A ...
Страница 1975: ......