2 Parameters
2.2 List of parameters
SINAMICS G130/G150
122
List Manual (LH2), 07/2016, A5E03263479A
Description:
Display and BICO output for the status of the inputs/outputs of the power unit contactors.
The display is activated in p0212.5.
r0256.0...31
CO/BO: Power unit contactor inputs/outputs status / PU contact IO stat
VECTOR_G, B_INF
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Unsigned32
Dyn. index:
-
Func. diagram:
9814
P-Group:
Displays, signals
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- -
-
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
PDS0 precharging/line contactor control
output
High
Low
-
01
PDS0 precharging/line contactor feedback
signal input
High
Low
-
02
PDS0 bypass contactor control output
High
Low
-
03
PDS0 bypass contactor feedback signal
input
High
Low
-
04
PDS1 precharging/line contactor control
output
High
Low
-
05
PDS1 precharging/line contactor feedback
signal input
High
Low
-
06
PDS1 bypass contactor control output
High
Low
-
07
PDS1 bypass contactor feedback signal
input
High
Low
-
08
PDS2 precharging/line contactor control
output
High
Low
-
09
PDS2 precharging/line contactor feedback
signal input
High
Low
-
10
PDS2 bypass contactor control output
High
Low
-
11
PDS2 bypass contactor feedback signal
input
High
Low
-
12
PDS3 precharging/line contactor control
output
High
Low
-
13
PDS3 precharging/line contactor feedback
signal input
High
Low
-
14
PDS3 bypass contactor control output
High
Low
-
15
PDS3 bypass contactor feedback signal
input
High
Low
-
16
PDS4 precharging/line contactor control
output
High
Low
-
17
PDS4 precharging/line contactor feedback
signal input
High
Low
-
18
PDS4 bypass contactor control output
High
Low
-
19
PDS4 bypass contactor feedback signal
input
High
Low
-
20
PDS5 precharging/line contactor control
output
High
Low
-
21
PDS5 precharging/line contactor feedback
signal input
High
Low
-
22
PDS5 bypass contactor control output
High
Low
-
23
PDS5 bypass contactor feedback signal
input
High
Low
-
24
PDS6 precharging/line contactor control
output
High
Low
-
25
PDS6 precharging/line contactor feedback
signal input
High
Low
-
26
PDS6 bypass contactor control output
High
Low
-
Содержание SINAMICS G130
Страница 1: ...s SINAMICS SINAMICS G130 G150 List Manual 07 2016 Edition ...
Страница 2: ......
Страница 8: ...Preface SINAMICS G130 G150 8 List Manual LH2 07 2016 A5E03263479A ...
Страница 1940: ...4 Faults and alarms 4 2 List of faults and alarms SINAMICS G130 G150 1940 List Manual LH2 07 2016 A5E03263479A ...
Страница 1960: ...A Appendix A 3 References SINAMICS G130 G150 1960 List Manual LH2 07 2016 A5E03263479A ...
Страница 1974: ...Index SINAMICS G130 G150 1974 List Manual LH2 07 2016 A5E03263479A ...
Страница 1975: ......