2 Parameters
2.2 List of parameters
SINAMICS G130/G150
406
List Manual (LH2), 07/2016, A5E03263479A
Description:
Displays the total supplementary torque.
The displayed value is the total of supplementary torque values 1 and 2 (p1511, p1512, p1513, p1514).
Description:
Displays the total supplementary torque and the accelerating torque.
The displayed value is the total of the smoothed supplementary torque and the accelerating torque (p1516 =
p1518[1] + r1515).
Description:
Sets the smoothing time constant of the accelerating torque.
Note:
For servo drives, the following applies:
- For p1402.4 = 1, the highest dynamic performance is achieved with p1517 = 0 ms.
- in encoderless operation, p1517 should be set >= 0.5 ms; for an induction motor with current displacement rotor
p1517 >= 20 ms is recommended.
For vector drives, the following applies:
- the acceleration pre-control is inhibited if the smoothing is set to the maximum value.
Description:
Displays the accelerating torque for pre-control of the speed controller.
Index:
[0] = Unsmoothed
[1] = Smoothed
Dependency:
Refer to: p0341, p0342, p1496
r1515
Supplementary torque total / M_suppl total
VECTOR_G (n/M)
Can be changed:
-
Calculated:
-
Access level:
2
Data type:
FloatingPoint32
Dyn. index:
-
Func. diagram:
6020, 6060
P-Group:
Closed-loop control
Unit group:
7_1
Unit selection:
p0505
Not for motor type:
REL
Scaling:
p2003
Expert list:
1
Min Max
Factory
setting
- [Nm]
- [Nm]
- [Nm]
r1516
CO: Supplementary torque and acceleration torque / M M_accel
VECTOR_G (n/M)
Can be changed:
-
Calculated:
-
Access level:
2
Data type:
FloatingPoint32
Dyn. index:
-
Func. diagram:
6060
P-Group:
Closed-loop control
Unit group:
7_1
Unit selection:
p0505
Not for motor type:
REL
Scaling:
p2003
Expert list:
1
Min Max
Factory
setting
- [Nm]
- [Nm]
- [Nm]
p1517[0...n]
Accelerating torque smoothing time constant / M_accel T_smooth
VECTOR_G (n/M)
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
FloatingPoint32
Dyn. index:
DDS, p0180
Func. diagram:
5042, 5210,
6060
P-Group:
Closed-loop control
Unit group:
-
Unit selection:
-
Not for motor type:
REL
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0.00 [ms]
100.00 [ms]
4.00 [ms]
r1518[0...1]
CO: Accelerating torque / M_accel
VECTOR_G (n/M)
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
FloatingPoint32
Dyn. index:
-
Func. diagram:
6060
P-Group:
Closed-loop control
Unit group:
7_1
Unit selection:
p0505
Not for motor type:
REL
Scaling:
p2003
Expert list:
1
Min Max
Factory
setting
- [Nm]
- [Nm]
- [Nm]
Содержание SINAMICS G130
Страница 1: ...s SINAMICS SINAMICS G130 G150 List Manual 07 2016 Edition ...
Страница 2: ......
Страница 8: ...Preface SINAMICS G130 G150 8 List Manual LH2 07 2016 A5E03263479A ...
Страница 1940: ...4 Faults and alarms 4 2 List of faults and alarms SINAMICS G130 G150 1940 List Manual LH2 07 2016 A5E03263479A ...
Страница 1960: ...A Appendix A 3 References SINAMICS G130 G150 1960 List Manual LH2 07 2016 A5E03263479A ...
Страница 1974: ...Index SINAMICS G130 G150 1974 List Manual LH2 07 2016 A5E03263479A ...
Страница 1975: ......