SINAMICS G130/G150
List Manual (LH2), 07/2016, A5E03263479A
513
2 Parameters
2.2 List of parameters
Notice:
Where there is a multiple interconnection of a connector output, all the connector inputs must either have Integer or
FloatingPoint data types.
A BICO interconnection for a single PZD can only take place either on r2050 or r2060.
Note:
IF1: Interface 1
Description:
Selects the PZD (actual values) with double word format to be sent to the fieldbus controller.
Index:
[0] = PZD 1 + 2
[1] = PZD 2 + 3
[2] = PZD 3 + 4
[3] = PZD 4 + 5
[4] = PZD 5 + 6
[5] = PZD 6 + 7
[6] = PZD 7 + 8
[7] = PZD 8 + 9
[8] = PZD 9 + 10
[9] = PZD 10 + 11
[10] = PZD 11 + 12
[11] = PZD 12 + 13
[12] = PZD 13 + 14
[13] = PZD 14 + 15
[14] = PZD 15 + 16
[15] = PZD 16 + 17
[16] = PZD 17 + 18
[17] = PZD 18 + 19
[18] = PZD 19 + 20
[19] = PZD 20 + 21
[20] = PZD 21 + 22
[21] = PZD 22 + 23
[22] = PZD 23 + 24
[23] = PZD 24 + 25
[24] = PZD 25 + 26
[25] = PZD 26 + 27
[26] = PZD 27 + 28
[27] = PZD 28 + 29
[28] = PZD 29 + 30
[29] = PZD 30 + 31
[30] = PZD 31 + 32
Dependency:
Refer to: p2051
Notice:
A BICO interconnection for a single PZD can only take place either on p2051 or p2061.
The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
Note:
IF1: Interface 1
Description:
Selects the PZD (actual values) with double word format to be sent to the fieldbus controller.
Index:
[0] = PZD 1 + 2
[1] = PZD 2 + 3
p2061[0...30]
CI: IF1 PROFIdrive PZD send double word / IF1 PZD send DW
VECTOR_G
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
Unsigned32 / Integer32
Dyn. index:
-
Func. diagram:
2470
P-Group:
Communications
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
4000H
Expert list:
1
Min Max
Factory
setting
- -
0
p2061[0...10]
CI: IF1 PROFIdrive PZD send double word / IF1 PZD send DW
ENC
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
Unsigned32 / Integer32
Dyn. index:
-
Func. diagram:
2470
P-Group:
Communications
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
4000H
Expert list:
1
Min Max
Factory
setting
- -
0
Содержание SINAMICS G130
Страница 1: ...s SINAMICS SINAMICS G130 G150 List Manual 07 2016 Edition ...
Страница 2: ......
Страница 8: ...Preface SINAMICS G130 G150 8 List Manual LH2 07 2016 A5E03263479A ...
Страница 1940: ...4 Faults and alarms 4 2 List of faults and alarms SINAMICS G130 G150 1940 List Manual LH2 07 2016 A5E03263479A ...
Страница 1960: ...A Appendix A 3 References SINAMICS G130 G150 1960 List Manual LH2 07 2016 A5E03263479A ...
Страница 1974: ...Index SINAMICS G130 G150 1974 List Manual LH2 07 2016 A5E03263479A ...
Страница 1975: ......