2 Parameters
2.2 List of parameters
SINAMICS G130/G150
640
List Manual (LH2), 07/2016, A5E03263479A
0 < r3996[0] < 100:
Parameter write inhibited. The value shows how the calculations are progressing.
Index:
[0] = Progress calculations
[1] = Cause
Note:
For index 1:
Only for internal Siemens troubleshooting.
Description:
Displays whether the drive still has to be commissioned for the first time.
0 = Yes
2 = No
Description:
Displays whether the infeed must be commissioned for the first time.
0 = Yes
2 = No
Description:
Displays the actual value at the digital inputs.
This means that the actual input signal can be checked at terminal DI x or DI/DO x prior to switching from the
simulation mode (p4095.x = 1) to terminal mode (p4095.x = 0).
Note:
If a DI/DO is parameterized as output (p4028.x = 1), then r4021.x = 0 is displayed.
DI: Digital Input
DI/DO: Bidirectional Digital Input/Output
r3998[0...n]
First drive commissioning / First drv_comm
VECTOR_G
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Unsigned16
Dyn. index:
DDS, p0180
Func. diagram:
-
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0 65535
-
r3998
First infeed commissioning / First inf_comm
B_INF
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Unsigned16
Dyn. index:
-
Func. diagram:
-
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0 65535
-
r4021
TM31 digital inputs terminal actual value / TM31 DI act value
TM31
Can be changed:
-
Calculated:
-
Access level:
2
Data type:
Unsigned32
Dyn. index:
-
Func. diagram:
9549, 9550,
9552, 9560, 9562
P-Group:
Commands
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- -
-
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
DI 0 (X520.1)
High
Low
-
01
DI 1 (X520.2)
High
Low
-
02
DI 2 (X520.3)
High
Low
-
03
DI 3 (X520.4)
High
Low
-
04
DI 4 (X530.1)
High
Low
-
05
DI 5 (X530.2)
High
Low
-
06
DI 6 (X530.3)
High
Low
-
07
DI 7 (X530.4)
High
Low
-
08
DI/DO 8 (X541.2)
High
Low
-
09
DI/DO 9 (X541.3)
High
Low
-
10
DI/DO 10 (X541.4)
High
Low
-
11
DI/DO 11 (X541.5)
High
Low
-
Содержание SINAMICS G130
Страница 1: ...s SINAMICS SINAMICS G130 G150 List Manual 07 2016 Edition ...
Страница 2: ......
Страница 8: ...Preface SINAMICS G130 G150 8 List Manual LH2 07 2016 A5E03263479A ...
Страница 1940: ...4 Faults and alarms 4 2 List of faults and alarms SINAMICS G130 G150 1940 List Manual LH2 07 2016 A5E03263479A ...
Страница 1960: ...A Appendix A 3 References SINAMICS G130 G150 1960 List Manual LH2 07 2016 A5E03263479A ...
Страница 1974: ...Index SINAMICS G130 G150 1974 List Manual LH2 07 2016 A5E03263479A ...
Страница 1975: ......