2 Parameters
2.2 List of parameters
SINAMICS G130/G150
1062
List Manual (LH2), 07/2016, A5E03263479A
Description:
Sets the factor for the test torque of sequence 1 for the safe brake test.
The factor is referred to the holding torque of the brake (p10209).
Index:
[0] = Brake 1
[1] = Brake 2
Dependency:
Refer to: p10209, p10230, p10235
Note:
The test sequence is selected using p10230[4] or p10235.4.
Description:
Sets the test duration for sequence 1 for the safe brake test.
The test torque is available for this time at the closed brake.
Index:
[0] = Brake 1
[1] = Brake 2
Dependency:
Refer to: p10230, p10235
Note:
The test sequence is selected using p10230[4] or p10235.4.
The set time is rounded internally to an integer multiple of the monitoring clock cycle.
Description:
Sets the tolerated position deviation for sequence 1 for the safe brake test.
Index:
[0] = Brake 1
[1] = Brake 2
Dependency:
Refer to: p10230, p10235
Note:
The test sequence is selected using p10230[4] or p10235.4.
Description:
Sets the tolerated position deviation for sequence 1 for the safe brake test.
Index:
[0] = Brake 1
[1] = Brake 2
Dependency:
Refer to: p10230, p10235
p10210[0...1]
SI Motion SBT test torque factor sequence 1 / SBT M_test fact 1
VECTOR_G
Can be changed:
C2(95)
Calculated:
-
Access level:
3
Data type:
FloatingPoint32
Dyn. index:
-
Func. diagram:
2836
P-Group:
Safety Integrated
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0.30 1.00
1.00
p10211[0...1]
SI Motion SBT test duration sequence 1 / SBT t_test seq 1
VECTOR_G
Can be changed:
C2(95)
Calculated:
-
Access level:
3
Data type:
FloatingPoint32
Dyn. index:
-
Func. diagram:
2836
P-Group:
Safety Integrated
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
20 [ms]
10000 [ms]
1000 [ms]
p10212[0...1]
SI Motion SBT position tolerance sequence 1 / SBT pos_tol seq 1
VECTOR_G
Can be changed:
C2(95)
Calculated:
-
Access level:
3
Data type:
FloatingPoint32
Dyn. index:
-
Func. diagram:
2836
P-Group:
Safety Integrated
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0.001 [mm]
360.000 [mm]
1.000 [mm]
p10212[0...1]
SI Motion SBT position tolerance sequence 1 / SBT pos_tol seq 1
VECTOR_G (Safety
rot)
Can be changed:
C2(95)
Calculated:
-
Access level:
3
Data type:
FloatingPoint32
Dyn. index:
-
Func. diagram:
2836
P-Group:
Safety Integrated
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0.001 [°]
360.000 [°]
1.000 [°]
Содержание SINAMICS G130
Страница 1: ...s SINAMICS SINAMICS G130 G150 List Manual 07 2016 Edition ...
Страница 2: ......
Страница 8: ...Preface SINAMICS G130 G150 8 List Manual LH2 07 2016 A5E03263479A ...
Страница 1940: ...4 Faults and alarms 4 2 List of faults and alarms SINAMICS G130 G150 1940 List Manual LH2 07 2016 A5E03263479A ...
Страница 1960: ...A Appendix A 3 References SINAMICS G130 G150 1960 List Manual LH2 07 2016 A5E03263479A ...
Страница 1974: ...Index SINAMICS G130 G150 1974 List Manual LH2 07 2016 A5E03263479A ...
Страница 1975: ......