2 Parameters
2.2 List of parameters
SINAMICS G130/G150
454
List Manual (LH2), 07/2016, A5E03263479A
Description:
Displays the effective gain of the integral component of the controller for speed adaptation.
Description:
Displays the P component of the controller for speed adaptation.
Description:
Displays the I component of the controller for speed adaptation.
Description:
Displays estimated (speed) signals of the motor model.
r1773[0]: Displays the estimated (mechanical) slip of the motor model.
r1773[1]: Displays the estimated input speed of the motor model.
Index:
[0] = Slip speed estimated
[1] = Speed estimated
Description:
Sets the offset voltage in the alpha direction; this compensates the offset voltages of the drive converter/inverter at
low speeds. The value is valid for the rated (nominal) pulse frequency of the power unit.
Note:
The value is pre-set during the rotating measurement.
r1768
Motor model speed adaptation Vi effective / MotM n_ada Vi act
VECTOR_G (n/M)
Can be changed:
-
Calculated:
-
Access level:
4
Data type:
FloatingPoint32
Dyn. index:
-
Func. diagram:
-
P-Group:
Closed-loop control
Unit group:
-
Unit selection:
-
Not for motor type:
SESM, REL
Scaling:
p2001
Expert list:
1
Min Max
Factory
setting
- -
-
r1770
CO: Motor model speed adaptation proportional component / MotMod n_adapt Kp
VECTOR_G (n/M)
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
FloatingPoint32
Dyn. index:
-
Func. diagram:
6730
P-Group:
Closed-loop control
Unit group:
3_1
Unit selection:
p0505
Not for motor type:
SESM, REL
Scaling:
p2000
Expert list:
1
Min Max
Factory
setting
- [rpm]
- [rpm]
- [rpm]
r1771
CO: Motor model speed adaptation I comp. / MotMod n_adapt Tn
VECTOR_G (n/M)
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
FloatingPoint32
Dyn. index:
-
Func. diagram:
6730
P-Group:
Closed-loop control
Unit group:
3_1
Unit selection:
p0505
Not for motor type:
SESM, REL
Scaling:
p2000
Expert list:
1
Min Max
Factory
setting
- [rpm]
- [rpm]
- [rpm]
r1773[0...1]
Motor model slip speed / MotMod slip
VECTOR_G (n/M)
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
FloatingPoint32
Dyn. index:
-
Func. diagram:
-
P-Group:
Closed-loop control
Unit group:
3_1
Unit selection:
p0505
Not for motor type:
SESM, REL
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- [rpm]
- [rpm]
- [rpm]
p1774[0...n]
Motor model offset voltage compensation alpha / MotMod offs comp A
VECTOR_G (n/M)
Can be changed:
U, T
Calculated:
-
Access level:
4
Data type:
FloatingPoint32
Dyn. index:
DDS, p0180
Func. diagram:
-
P-Group:
Closed-loop control
Unit group:
-
Unit selection:
-
Not for motor type:
PMSM, SESM, REL
Scaling:
-
Expert list:
1
Min Max
Factory
setting
-5.000 [V]
5.000 [V]
0.000 [V]
Содержание SINAMICS G130
Страница 1: ...s SINAMICS SINAMICS G130 G150 List Manual 07 2016 Edition ...
Страница 2: ......
Страница 8: ...Preface SINAMICS G130 G150 8 List Manual LH2 07 2016 A5E03263479A ...
Страница 1940: ...4 Faults and alarms 4 2 List of faults and alarms SINAMICS G130 G150 1940 List Manual LH2 07 2016 A5E03263479A ...
Страница 1960: ...A Appendix A 3 References SINAMICS G130 G150 1960 List Manual LH2 07 2016 A5E03263479A ...
Страница 1974: ...Index SINAMICS G130 G150 1974 List Manual LH2 07 2016 A5E03263479A ...
Страница 1975: ......