2 Parameters
2.2 List of parameters
SINAMICS G130/G150
588
List Manual (LH2), 07/2016, A5E03263479A
Description:
Sets the mode for the time stamp
Value:
0:
Operating hours
1:
UTC format
2:
Operating hours + 01.01.2000
Notice:
For p3100 = 1:
The system prevents this setting from being changed. The parameter can only be influenced after "Set factory
setting" or with a "Project download".
Note:
RTC: Real-time clock
UTC: Universal Time Coordinates
For p3100 = 1:
Time of day synchronization is only possible with this setting.
The UTC time started, according to the definition on 01.01.1970 at 00:00:00 and is output in days and milliseconds.
Description:
Setting the UTC time.
This means that the drive system is synchronized to the time specified by the time master.
To start p3101[1] must be written to followed by p3101[0]. After writing to p3101[0], the UTC time is accepted.
Index:
[0] = Milliseconds
[1] = Days
Dependency:
Refer to: p3100
Description:
Displaying the current UTC time.
Index:
[0] = Milliseconds
[1] = Days
Dependency:
Refer to: p3100
p3100
RTC time stamp mode / RTC t_stamp mode
CU_G130_PN,
CU_G150_PN,
CU_G130_DP,
CU_G150_DP
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
Unsigned16
Dyn. index:
-
Func. diagram:
-
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0 2
2
p3101[0...1]
Setting UTC time / Set UTC time
CU_G130_PN,
CU_G150_PN,
CU_G130_DP,
CU_G150_DP
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
Unsigned32
Dyn. index:
-
Func. diagram:
-
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0 4294967295
0
r3102[0...1]
Displaying UTC time / Display UTC time
CU_G130_PN,
CU_G150_PN,
CU_G130_DP,
CU_G150_DP
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Unsigned32
Dyn. index:
-
Func. diagram:
-
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- -
-
Содержание SINAMICS G130
Страница 1: ...s SINAMICS SINAMICS G130 G150 List Manual 07 2016 Edition ...
Страница 2: ......
Страница 8: ...Preface SINAMICS G130 G150 8 List Manual LH2 07 2016 A5E03263479A ...
Страница 1940: ...4 Faults and alarms 4 2 List of faults and alarms SINAMICS G130 G150 1940 List Manual LH2 07 2016 A5E03263479A ...
Страница 1960: ...A Appendix A 3 References SINAMICS G130 G150 1960 List Manual LH2 07 2016 A5E03263479A ...
Страница 1974: ...Index SINAMICS G130 G150 1974 List Manual LH2 07 2016 A5E03263479A ...