SINAMICS G130/G150
List Manual (LH2), 07/2016, A5E03263479A
1075
2 Parameters
2.3 Parameters for data sets
p1605[0...n]
Pulse technique pattern configuration / Puls pattrn config
p1607[0...n]
Pulse technique stimulus / Puls stimulus
p1609[0...n]
I/f operation current setpoint / I/f op I_setp
p1610[0...n]
Torque setpoint static (sensorless) / M_set static
p1611[0...n]
Additional acceleration torque (sensorless) / M_suppl_accel
p1612[0...n]
Current setpoint magnetizing open-loop controlled / Id_set ctrl
p1616[0...n]
Current setpoint smoothing time / I_set T_smooth
p1619[0...n]
Setpoint/actual value tracking threshold / SetAct track thrsh
p1620[0...n]
Stator current minimum / I_stator min
p1621[0...n]
Changeover speed inner cos phi = 1 / n_chngov cos phi=1
p1622[0...n]
Field-generating current setpoint smoothing time constant / Id_setp T_smth
p1625[0...n]
Excitation current setpoint calibration / I_exc_setp cal
p1628[0...n]
Current model controller dynamic factor / I_mod_ctr dyn_fact
p1629[0...n]
Current model controller P gain / I_mod_ctrl Kp
p1630[0...n]
Current model controller integral time / I_mod_ctrl Tn
p1642[0...n]
Minimum excitation current / Min I_exc
p1643[0...n]
Minimum excitation current closed-loop control gain factor / I_exc_min Kp
p1653[0...n]
Current setpoint torque-generating smoothing time minimum / Isq_s T_smth min
p1654[0...n]
Curr. setpoint torque-gen. smoothing time field weakening range / Isq_s T_smth FW
p1656[0...n]
Current setpoint/Speed actual value filter activation / I_setp_filt act
p1657[0...n]
Current setpoint filter 1 type / I_set_filt 1 type
p1658[0...n]
Current setpoint filter 1 denominator natural frequency / I_set_filt1 fn_den
p1659[0...n]
Current setpoint filter 1 denominator damping / I_set_filt 1 D_den
p1660[0...n]
Current setpoint filter 1 numerator natural frequency / I_set_filt1 fn_num
p1661[0...n]
Current setpoint filter 1 numerator damping / I_set_filt 1 D_num
p1662[0...n]
Current setpoint filter 2 type / I_set_filt 2 type
p1663[0...n]
Current setpoint filter 2 denominator natural frequency / I_set_filt2 fn_den
p1664[0...n]
Current setpoint filter 2 denominator damping / I_set_filt 2 D_den
p1665[0...n]
Current setpoint filter 2 numerator natural frequency / I_set_filt2 fn_num
p1666[0...n]
Current setpoint filter 2 numerator damping / I_set_filt 2 D_num
p1677[0...n]
Speed actual value filter 5 type / n_act_filt 5 type
p1678[0...n]
Speed actual value filter 5 denominator natural frequency / n_act_filt5 fn_den
p1679[0...n]
Speed actual value filter 5 denominator damping / n_act_filt 5 D_den
p1680[0...n]
Speed actual value filter 5 numerator natural frequency / n_act_filt5 fn_num
p1681[0...n]
Speed actual value filter 5 numerator damping / n_act_filt 5 D_num
p1702[0...n]
Isd current controller pre-control scaling / Isd_ctr_prectrScal
p1703[0...n]
Isq current controller pre-control scaling / Isq_ctr_prectrScal
p1704[0...n]
Isq current controller pre-control EMF scaling / Isq_ctrl EMF scal
p1705[0...n]
Flux setpoint/actual value tracking threshold / Flux track thresh
p1715[0...n]
Current controller P gain / I_ctrl Kp
p1717[0...n]
Current controller integral-action time / I_ctrl Tn
p1720[0...n]
Current controller d axis p gain / Id_ctrl Kp
p1722[0...n]
Current controller d axis integral time / I_ctrl d-axis Tn
p1726[0...n]
Quadrature arm decoupling scaling / Transv_decpl scal
p1727[0...n]
Quadrature arm decoupling at voltage limit scaling / TrnsvDecplVmaxScal
p1730[0...n]
Isd controller integral component shutdown threshold / Isd ctrl Tn shutd
p1731[0...n]
Isd controller combination current time component / Isd ctr I_combi T1
p1740[0...n]
Gain resonance damping for encoderless closed-loop control / Gain res_damp
p1744[0...n]
Motor model speed threshold stall detection / MotMod n_thr stall
p1745[0...n]
Motor model error threshold stall detection / MotMod ThreshStall
p1748[0...n]
Motor model lower changeover speed n_set -> n_act / MotMod low n_chng
p1749[0...n]
Motor model upper changeover speed / increase changeover speed / Up/incr n_chngov
p1750[0...n]
Motor model configuration / MotMod config
p1752[0...n]
Motor model changeover speed operation with encoder / MotMod n_chgov enc
p1753[0...n]
Motor model changeover speed hysteresis operation with encoder / MotMod n_chgovHysE
Содержание SINAMICS G130
Страница 1: ...s SINAMICS SINAMICS G130 G150 List Manual 07 2016 Edition ...
Страница 2: ......
Страница 8: ...Preface SINAMICS G130 G150 8 List Manual LH2 07 2016 A5E03263479A ...
Страница 1940: ...4 Faults and alarms 4 2 List of faults and alarms SINAMICS G130 G150 1940 List Manual LH2 07 2016 A5E03263479A ...
Страница 1960: ...A Appendix A 3 References SINAMICS G130 G150 1960 List Manual LH2 07 2016 A5E03263479A ...
Страница 1974: ...Index SINAMICS G130 G150 1974 List Manual LH2 07 2016 A5E03263479A ...
Страница 1975: ......