SINAMICS G130/G150
List Manual (LH2), 07/2016, A5E03263479A
1085
2 Parameters
2.3 Parameters for data sets
r7226[0...n]
CO: Par_circuit phase current actual value phase U offset / I_phase U offset
r7227[0...n]
CO: Par_circuit phase current actual value phase V offset / I_phase V offset
r7228[0...n]
CO: Par_circuit phase current actual value phase W offset / I_phase W offset
r7229[0...n]
CO: Par_circuit phase current actual value sum U, V, W / I_phase sum UVW
r7230[0...n]
CO: Par_circuit DC link voltage actual value / Vdc_act
r7231[0...n]
CO: Par_circuit phase voltage actual value phase U / U_phase U act val
r7232[0...n]
CO: Par_circuit phase voltage actual value phase V / U_phase V act val
r7233[0...n]
CO: Par_circuit phase voltage actual value phase W / U_phase W act val
r7240[0...n]
Par_circuit gating unit status word 1 / Gating unit ZSW1
r7740[0...n]
IGBT power cycling counter valve 1 / IGBT load count 1
r7741[0...n]
IGBT power cycling counter valve 2 / IGBT load count 2
r7742[0...n]
IGBT power cycling counter valve 3 / IGBT load count 3
r7743[0...n]
IGBT power cycling counter valve 4 / IGBT load count 4
r7744[0...n]
IGBT power cycling counter valve 5 / IGBT load count 5
r7745[0...n]
IGBT power cycling counter valve 6 / IGBT load count 6
p7786[0...n]
Service report / Service report
p9671[0...n]
SI module identifier Motor Module / Module ID MM
Содержание SINAMICS G130
Страница 1: ...s SINAMICS SINAMICS G130 G150 List Manual 07 2016 Edition ...
Страница 2: ......
Страница 8: ...Preface SINAMICS G130 G150 8 List Manual LH2 07 2016 A5E03263479A ...
Страница 1940: ...4 Faults and alarms 4 2 List of faults and alarms SINAMICS G130 G150 1940 List Manual LH2 07 2016 A5E03263479A ...
Страница 1960: ...A Appendix A 3 References SINAMICS G130 G150 1960 List Manual LH2 07 2016 A5E03263479A ...
Страница 1974: ...Index SINAMICS G130 G150 1974 List Manual LH2 07 2016 A5E03263479A ...
Страница 1975: ......