2 Parameters
2.2 List of parameters
SINAMICS G130/G150
156
List Manual (LH2), 07/2016, A5E03263479A
Description:
Displays the damping inductance of the separately excited synchronous motor in the rotor direction (d-axis).
Description:
Displays the damping inductance of a separately excited synchronous motor quadrature to the rotor direction (q
axis).
Description:
Displays the magnetizing inductance of the motor.
For separately excited synchronous motors:
Displays the saturated magnetizing inductance in the rotor direction (d-axis).
Note:
The parameter is not used for synchronous motors (p0300 = 2xx).
Description:
Displays the saturated magnetizing inductance of a separately excited synchronous motor quadrature to the rotor
direction (q axis).
r0380[0...n]
Motor damping inductance d axis / Mot L_damp d
VECTOR_G
Can be changed:
-
Calculated:
-
Access level:
4
Data type:
FloatingPoint32
Dyn. index:
MDS, p0130
Func. diagram:
-
P-Group:
Motor
Unit group:
15_1
Unit selection:
p0349
Not for motor type:
ASM, PMSM, REL,
RESM
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- [mH]
- [mH]
- [mH]
r0381[0...n]
Motor damping inductance q axis / Mot L_damp q
VECTOR_G
Can be changed:
-
Calculated:
-
Access level:
4
Data type:
FloatingPoint32
Dyn. index:
MDS, p0130
Func. diagram:
-
P-Group:
Motor
Unit group:
15_1
Unit selection:
p0349
Not for motor type:
ASM, PMSM, REL,
RESM
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- [mH]
- [mH]
- [mH]
r0382[0...n]
Motor magnetizing inductance transformed / Lh d axis saturated / Mot L_m tr/Lhd sat
VECTOR_G
Can be changed:
-
Calculated:
-
Access level:
4
Data type:
FloatingPoint32
Dyn. index:
MDS, p0130
Func. diagram:
-
P-Group:
Motor
Unit group:
15_1
Unit selection:
p0349
Not for motor type:
PMSM, REL, RESM
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- [mH]
- [mH]
- [mH]
r0383[0...n]
Motor magnetizing inductance q axis saturated / Mot L_magn q sat
VECTOR_G
Can be changed:
-
Calculated:
-
Access level:
4
Data type:
FloatingPoint32
Dyn. index:
MDS, p0130
Func. diagram:
-
P-Group:
Motor
Unit group:
15_1
Unit selection:
p0349
Not for motor type:
ASM, PMSM, REL,
RESM
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- [mH]
- [mH]
- [mH]
Содержание SINAMICS G130
Страница 1: ...s SINAMICS SINAMICS G130 G150 List Manual 07 2016 Edition ...
Страница 2: ......
Страница 8: ...Preface SINAMICS G130 G150 8 List Manual LH2 07 2016 A5E03263479A ...
Страница 1940: ...4 Faults and alarms 4 2 List of faults and alarms SINAMICS G130 G150 1940 List Manual LH2 07 2016 A5E03263479A ...
Страница 1960: ...A Appendix A 3 References SINAMICS G130 G150 1960 List Manual LH2 07 2016 A5E03263479A ...
Страница 1974: ...Index SINAMICS G130 G150 1974 List Manual LH2 07 2016 A5E03263479A ...
Страница 1975: ......