SINAMICS G130/G150
List Manual (LH2), 07/2016, A5E03263479A
979
2 Parameters
2.2 List of parameters
Dependency:
Refer to: r9732
Notice:
For index 2:
This SLS velocity limit can, as a result of conversion into the internal monitoring format, deviate from the specified
SLS velocity limit (see r9732).
Note:
The display is updated in the safety monitoring clock cycle.
For linear axes, the following unit applies: millimeters per minute
For rotary axes, the following unit applies: revolutions per minute
Description:
Displays the velocity actual values for the motion monitoring functions on the Control Unit.
Index:
[0] = Load-side velocity actual value on the Control Unit
[1] = Actual SAM/SBR velocity limit on the Control Unit
[2] = Actual SLS velocity limit on the Control Unit
Dependency:
Refer to: r9732
Notice:
For index 2:
This SLS velocity limit can, as a result of conversion into the internal monitoring format, deviate from the specified
SLS velocity limit (see r9732).
Note:
The display is updated in the safety monitoring clock cycle.
For linear axes, the following unit applies: millimeters per minute
For rotary axes, the following unit applies: revolutions per minute
Description:
Control signal 1 for safety-relevant motion monitoring functions.
Note:
TfS: Traverse to fixed stop
Description:
Control signal 2 for safety-relevant motion monitoring functions.
r9714[0...2]
CO: SI motion diagnostics velocity / SI Mtn diag v
VECTOR_G (Safety
rot)
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
FloatingPoint32
Dyn. index:
-
Func. diagram:
-
P-Group:
Safety Integrated
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- [rpm]
- [rpm]
- [rpm]
r9718.23
CO/BO: SI Motion control signals 1 / SI Mtn ctrl_sig 1
VECTOR_G
Can be changed:
-
Calculated:
-
Access level:
4
Data type:
Unsigned32
Dyn. index:
-
Func. diagram:
-
P-Group:
Safety Integrated
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- -
-
Bit field:
Bit
Signal name
1 signal
0 signal
FP
23
Set offset for TfS to the actual torque
Set
Reset
-
r9719.0...31
CO/BO: SI Motion control signals 2 / SI Mtn ctrl_sig 2
VECTOR_G
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Unsigned32
Dyn. index:
-
Func. diagram:
-
P-Group:
Safety Integrated
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- -
-
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
De-select SOS/SLS (SBH/SG)
Yes
No
-
01
De-select SOS (SBH)
Yes
No
-
03
Select SLS (SG) bit 0
Set
Not set
-
04
Select SLS (SG) bit 1
Set
Not set
-
05
Deselect SDI positive
Yes
No
-
06
Deselect SDI negative
Yes
No
-
07
Deselect SLP
Yes
No
-
Содержание SINAMICS G130
Страница 1: ...s SINAMICS SINAMICS G130 G150 List Manual 07 2016 Edition ...
Страница 2: ......
Страница 8: ...Preface SINAMICS G130 G150 8 List Manual LH2 07 2016 A5E03263479A ...
Страница 1940: ...4 Faults and alarms 4 2 List of faults and alarms SINAMICS G130 G150 1940 List Manual LH2 07 2016 A5E03263479A ...
Страница 1960: ...A Appendix A 3 References SINAMICS G130 G150 1960 List Manual LH2 07 2016 A5E03263479A ...
Страница 1974: ...Index SINAMICS G130 G150 1974 List Manual LH2 07 2016 A5E03263479A ...
Страница 1975: ......