2 Parameters
2.2 List of parameters
SINAMICS G130/G150
888
List Manual (LH2), 07/2016, A5E03263479A
Note:
DAP ID: Device Access Point ID
DAP ID = 20008 hex: SINAMICS CBE20 V4.6
DAP ID = 20009 hex: SINAMICS CBE20 V4.7
DAP ID = 2000A hex: SINAMICS CBE20 V4.8
DAP ID = 20209 hex: SINAMICS CBE25 V4.7
Description:
Displays the controller assignment of a PROFINET subslot on the actual drive object.
The display is only relevant for Shared Device (p8929 = 2).
Index:
[0] = Subslot 2 PROFIsafe
[1] = Subslot 3 PZD telegram
[2] = Subslot 4 PZD supplementary data
Dependency:
Refer to: r8961, r8962
Note:
Example:
If the parameter contains the value 2 in index [1], then this means that subslot 3 is assigned to controller 2.
Description:
Displays the IP address of the first PROFINET controller connected with the device via PN onboard.
Description:
Displays the IP address of the second PROFINET controller connected with the device via PN onboard.
The display is only relevant for Shared Device (p8929 = 2) or system redundancy.
Description:
Setting for the behavior of a PROFIsafe communication connection depending on another isochronous
communication connection.
Value:
0:
No
1:
Yes
Recommendation:
A value of 1 is recommended, if problems are encountered with the PROFIsafe connection when synchronizing.
r8960[0...2]
PN subslot controller assignment / PN subslot assign
CU_G130_PN,
CU_G150_PN,
CU_G130_DP,
CU_G150_DP,
VECTOR_G, B_INF,
TM31, TM120, TM150,
TB30, ENC
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Unsigned8
Dyn. index:
-
Func. diagram:
-
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0 8
-
r8961[0...3]
PN IP Address Remote Controller 1 / IP Addr Rem Ctrl1
CU_G130_PN,
CU_G150_PN
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Unsigned8
Dyn. index:
-
Func. diagram:
-
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0 255
-
r8962[0...3]
PN IP Address Remote Controller 2 / IP Addr Rem Ctrl2
CU_G130_PN,
CU_G150_PN
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Unsigned8
Dyn. index:
-
Func. diagram:
-
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0 255
-
p8969
PROFIsafe wait for clock synchronization / PS wait sync
CU_G130_PN,
CU_G150_PN,
CU_G130_DP,
CU_G150_DP
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
Integer16
Dyn. index:
-
Func. diagram:
-
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0 1
0
Содержание SINAMICS G130
Страница 1: ...s SINAMICS SINAMICS G130 G150 List Manual 07 2016 Edition ...
Страница 2: ......
Страница 8: ...Preface SINAMICS G130 G150 8 List Manual LH2 07 2016 A5E03263479A ...
Страница 1940: ...4 Faults and alarms 4 2 List of faults and alarms SINAMICS G130 G150 1940 List Manual LH2 07 2016 A5E03263479A ...
Страница 1960: ...A Appendix A 3 References SINAMICS G130 G150 1960 List Manual LH2 07 2016 A5E03263479A ...
Страница 1974: ...Index SINAMICS G130 G150 1974 List Manual LH2 07 2016 A5E03263479A ...
Страница 1975: ......