SINAMICS G130/G150
List Manual (LH2), 07/2016, A5E03263479A
733
2 Parameters
2.2 List of parameters
Description:
Displays the IDs of all the invalid Technology Extensions installed on the memory card/device memory.
r4978[0...8]: Identifier of invalid Technology Extension 1
r4978[9...17]: Identifier of invalid Technology Extension 2, ...
Dependency:
Refer to: r4975, r4976, r4979
Notice:
An index cannot be accessed if there is no valid Technology Extension available.
Note:
TEC: Technology Extension
Description:
Displays the error code of the invalid Technology Extensions installed on the memory card/device memory.
r4979[0]: Fault value of Technology Extension 1
r4979[1]: Fault value of Technology Extension 2, ...
Dependency:
Refer to: r4975, r4976, r4978
Notice:
An index cannot be accessed if there is no valid Technology Extension available.
Note:
TEC: Technology Extension
The value in the error code must be interpreted in binary form. The bits have the following meaning:
Bit 0: Incompatible version of the TEC interface.
Bit 1: Technology Extension could not be loaded.
Bit 2: Incorrect description files.
Bit 3: Technology Extension does not define a CPU type.
Bit 4: Technology Extension for this device not available (incorrect CPU type).
Bit 5: Technology Extension for this device not available (incorrect type ID).
Bit 6: Incorrect description files (Const/Startup incompatible).
Description:
Displays the number of Technology Extensions installed on the memory card/device memory.
Dependency:
Refer to: r4986, r4987, r4988, r4989, r4990, r4991, r4992, r4993, r4994
Note:
TEC: Technology Extension
r4978[0...n]
TEC invalid identifier / TEC inval ID
CU_G130_PN,
CU_G150_PN,
CU_G130_DP,
CU_G150_DP
Can be changed:
-
Calculated:
-
Access level:
4
Data type:
Unsigned8
Dyn. index:
r4976
Func. diagram:
-
P-Group:
OEM range
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- -
-
r4979[0...n]
TEC invalid error code / TEC inv error code
CU_G130_PN,
CU_G150_PN,
CU_G130_DP,
CU_G150_DP
Can be changed:
-
Calculated:
-
Access level:
4
Data type:
Unsigned32
Dyn. index:
r4975
Func. diagram:
-
P-Group:
OEM range
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- -
-
r4985
TEC number / TEC qty
CU_G130_PN,
CU_G150_PN,
CU_G130_DP,
CU_G150_DP
Can be changed:
-
Calculated:
-
Access level:
4
Data type:
Unsigned16
Dyn. index:
-
Func. diagram:
-
P-Group:
OEM range
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0 16
-
Содержание SINAMICS G130
Страница 1: ...s SINAMICS SINAMICS G130 G150 List Manual 07 2016 Edition ...
Страница 2: ......
Страница 8: ...Preface SINAMICS G130 G150 8 List Manual LH2 07 2016 A5E03263479A ...
Страница 1940: ...4 Faults and alarms 4 2 List of faults and alarms SINAMICS G130 G150 1940 List Manual LH2 07 2016 A5E03263479A ...
Страница 1960: ...A Appendix A 3 References SINAMICS G130 G150 1960 List Manual LH2 07 2016 A5E03263479A ...
Страница 1974: ...Index SINAMICS G130 G150 1974 List Manual LH2 07 2016 A5E03263479A ...
Страница 1975: ......