SINAMICS G130/G150
List Manual (LH2), 07/2016, A5E03263479A
19
2 Parameters
2.1 Overview of parameters
A parameter can belong to a single, multiple, or all drive objects.
The following information relating to "Drive object" and "Function module" can be displayed
under the parameter number:
Table 2-1
Data in the "Drive object (function module)" field
Drive object (function
module)
Type
Meaning
All objects
-
This parameter is used by all drive objects.
B_INF
30
Basic Infeed closed-loop control
Unregulated line infeed unit (without regenerative feedback) for rectifying the line
voltage of the DC link.
B_INF (Rec)
-
Basic Infeed with "Recorder" function module (r0108.5)
B_INF (parallel)
-
Basic Infeed with "Parallel connection" function module (r0108.15).
B_INF (Brk Mod Ext)
-
Basic Infeed with "Braking Module external" function module (r0108.26).
B_INF (Cooling unit)
-
Basic Infeed with "Cooling unit" function module (r0108.28)
B_INF (PN CBE20)
-
Basic Infeed with "PROFINET CBE20" function module (r0108.31).
CU_G130_DP
SINAMICS G130 Control Unit with PROFIBUS interface.
CU_G130_DP (CAN)
-
SINAMICS G130 Control Unit with PROFIBUS interface and "CAN" function module
(p0108.29).
CU_G130_DP
(COMM BOARD)
SINAMICS G130 Control Unit with PROFIBUS interface and "COMM BOARD"
function module (p0108.30).
CU_G130_DP
(PN CBE20)
-
SINAMICS G130 Control Unit with PROFIBUS interface and "PROFINET CBE20"
function module (p0108.31).
CU_G130_PN
SINAMICS G130 Control Unit with PROFINET interface.
CU_G130_PN (CAN)
-
SINAMICS G130 Control Unit with PROFINET interface and "CAN" function module
(p0108.29).
CU_G130_PN
(COMM BOARD)
SINAMICS G130 Control Unit with PROFINET interface and "COMM BOARD"
function module (p0108.30).
CU_G130_PN
(PN CBE20)
SINAMICS G130 Control Unit with PROFINET interface and "PROFINET CBE20"
function module (p0108.31).
CU_G150_DP
SINAMICS G150 Control Unit with PROFIBUS interface.
CU_G150_DP (CAN)
-
SINAMICS G150 Control Unit with PROFIBUS interface and "CAN" function module
(p0108.29).
CU_G150_DP
(COMM BOARD)
SINAMICS G150 Control Unit with PROFIBUS interface and "COMM BOARD"
function module (p0108.30).
CU_G150_DP
(PN CBE20)
-
SINAMICS G150 Control Unit with PROFIBUS interface and "PROFINET CBE20"
function module (p0108.31).
CU_G150_PN
SINAMICS G150 Control Unit with PROFINET interface.
CU_G150_PN (CAN)
-
SINAMICS G150 Control Unit with PROFINET interface and "CAN" function module
(p0108.29).
CU_G150_PN
(COMM BOARD)
SINAMICS G150 Control Unit with PROFINET interface and "COMM BOARD"
function module (p0108.30).
CU_G150_PN
(PN CBE20)
SINAMICS G150 Control Unit with PROFINET interface and "PROFINET CBE20"
function module (p0108.31).
Содержание SINAMICS G130
Страница 1: ...s SINAMICS SINAMICS G130 G150 List Manual 07 2016 Edition ...
Страница 2: ......
Страница 8: ...Preface SINAMICS G130 G150 8 List Manual LH2 07 2016 A5E03263479A ...
Страница 1940: ...4 Faults and alarms 4 2 List of faults and alarms SINAMICS G130 G150 1940 List Manual LH2 07 2016 A5E03263479A ...
Страница 1960: ...A Appendix A 3 References SINAMICS G130 G150 1960 List Manual LH2 07 2016 A5E03263479A ...
Страница 1974: ...Index SINAMICS G130 G150 1974 List Manual LH2 07 2016 A5E03263479A ...
Страница 1975: ......